Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width125mm
Supporting protocol for LONNo
Height18.4mm
Number of HW-interfaces RS-2320
Time delay at signal exchange5.25 - 5.75ms
Depth65.1mm
Number of HW-interfaces industrial Ethernet0
Input current at signal 14.5mA
Number of HW-interfaces RS-4220
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Number of HW-interfaces USB0
With optical interfaceNo
Number of HW-interfaces other0
Type of voltage (input voltage)AC/DC
Number of HW-interfaces parallel0
Suitable for safety functionsNo
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Short-circuit protection, outputs availableNo
Type of digital outputNone
Type of electric connectionScrew-/spring clamp connection
Rail mounting possibleNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Output current0A
Explosion safety category for dustNone
Number of HW-interfaces Wireless0
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Supporting protocol for INTERBUS-SafetyNo
Fieldbus connection over separate bus coupler possibleYes
Explosion safety category for gasNone
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
System accessoryYes
Radio standard BluetoothNo
Rack-assembly possibleYes
Wall mounting/direct mountingNo
Front built-in possibleNo
Supply voltage DC24 - 24V
Performance level according to EN ISO 13849-1None
Supporting protocol for Foundation FieldbusNo
IO link masterNo
Radio standard Wi-Fi 802.11No
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Type of output voltageAC/DC
Digital outputs configurableNo
Digital inputs configurableNo
Supply voltage AC 50 Hz- - -V
Supporting protocol for PROFIsafeNo
Permitted voltage at input-3 - 30V
Permitted voltage at output0 - 0V
Radio standard GPRSNo
Supply voltage AC 60 Hz- - -V
Radio standard GSMNo
SIL according to IEC 61508None
Radio standard UMTSNo
Number of digital inputs6
Number of digital outputs0
Voltage type of supply voltageAC/DC
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

STBDDI3615K | 24VDC in 6PT Basic KIT Conns,base

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

125mm

Supporting protocol for LON

Height

18.4mm

Number of HW-interfaces RS-232

0

Time delay at signal exchange

5.25 .. 5.75ms

Depth

65.1mm

Number of HW-interfaces industrial Ethernet

0

Input current at signal 1

4.5mA

Number of HW-interfaces RS-422

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

Number of HW-interfaces USB

0

With optical interface

Number of HW-interfaces other

0

Type of voltage (input voltage)

AC/DC

Number of HW-interfaces parallel

0

Suitable for safety functions

Number of HW-interfaces RS-485

0

Number of HW-interfaces serial TTY

0

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for CAN

Short-circuit protection, outputs available

Type of digital output

None

Type of electric connection

Screw-/spring clamp connection

Rail mounting possible

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Output current

0A

Explosion safety category for dust

None

Number of HW-interfaces Wireless

0

Appendant operation agent (Ex ia)

Appendant operation agent (Ex ib)

Supporting protocol for INTERBUS-Safety

Fieldbus connection over separate bus coupler possible

Explosion safety category for gas

None

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

System accessory

Radio standard Bluetooth

Rack-assembly possible

Wall mounting/direct mounting

Front built-in possible

Supply voltage DC

24 .. 24V

Performance level according to EN ISO 13849-1

None

Supporting protocol for Foundation Fieldbus

IO link master

Radio standard Wi-Fi 802.11

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Type of output voltage

AC/DC

Digital outputs configurable

Digital inputs configurable

Supply voltage AC 50 Hz

- .. -V

Supporting protocol for PROFIsafe

Permitted voltage at input

-3 .. 30V

Permitted voltage at output

0 .. 0V

Radio standard GPRS

Supply voltage AC 60 Hz

- .. -V

Radio standard GSM

SIL according to IEC 61508

None

Radio standard UMTS

Number of digital inputs

6

Number of digital outputs

0

Voltage type of supply voltage

AC/DC

Degree of protection (IP)

IP20