Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Width125mm
Suitable for safety functionsNo
Input current at signal 14.5mA
Supporting protocol for LONNo
Height18.4mm
Time delay at signal exchange2 - 2ms
Number of HW-interfaces serial TTY0
Depth65.1mm
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-4220
Number of HW-interfaces USB0
Explosion safety category for dustNone
Supporting protocol for DeviceNetNo
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusNo
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Short-circuit protection, outputs availableNo
Type of voltage (input voltage)DC
Supporting protocol for SUCONETNo
Supporting protocol for TCP/IPNo
Fieldbus connection over separate bus coupler possibleYes
Number of HW-interfaces other0
Supporting protocol for KNXNo
Supporting protocol for other bus systemsNo
Type of electric connectionScrew connection
Output current0A
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
System accessoryYes
Explosion safety category for gasNone
With optical interfaceNo
Type of digital outputNone
Rail mounting possibleNo
Rack-assembly possibleYes
Wall mounting/direct mountingNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Appendant operation agent (Ex ib)No
Supply voltage AC 60 Hz- - -V
IO link masterNo
Supporting protocol for INTERBUS-SafetyNo
Performance level according to EN ISO 13849-1None
Front built-in possibleNo
Supporting protocol for PROFIsafeNo
Supporting protocol for AS-Interface Safety at WorkNo
Radio standard Wi-Fi 802.11No
Supporting protocol for EtherNet/IPNo
Supply voltage AC 50 Hz- - -V
Number of HW-interfaces Wireless0
Number of interfaces PROFINET0
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Radio standard BluetoothNo
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNet SafetyNo
Supply voltage DC24 - 24V
Appendant operation agent (Ex ia)No
Type of output voltageDC
Digital inputs configurableNo
Permitted voltage at output0 - 0V
Permitted voltage at input-3 - 30V
SIL according to IEC 61508None
Digital outputs configurableNo
Radio standard UMTSNo
Radio standard GPRSNo
Radio standard GSMNo
Number of digital inputs16
Number of digital outputs0
Voltage type of supply voltageDC
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user