Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width128.3mm
Height13.9mm
Suitable for safety functionsNo
Depth70mm
Input current at signal 1-mA
Number of HW-interfaces serial TTY0
Voltage type of supply voltageAC/DC
Number of digital outputs4
Supporting protocol for DeviceNetYes
Supporting protocol for CANYes
Time delay at signal exchange0.56 - 0.87ms
Number of HW-interfaces industrial Ethernet0
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4220
Supporting protocol for INTERBUSYes
Supporting protocol for PROFIBUSYes
Number of HW-interfaces other0
Number of HW-interfaces USB0
Supporting protocol for LONNo
With optical interfaceNo
Number of digital inputs0
Supporting protocol for KNXNo
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-2320
Supporting protocol for ASINo
Supporting protocol for ModbusYes
Supporting protocol for TCP/IPYes
Number of HW-interfaces parallel0
Type of voltage (input voltage)AC/DC
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Type of electric connectionScrew connection
Rail mounting possibleNo
Explosion safety category for dustNone
Fieldbus connection over separate bus coupler possibleYes
IO link masterNo
Type of digital outputOther
Number of HW-interfaces Wireless0
Appendant operation agent (Ex ib)No
Number of interfaces PROFINET0
System accessoryYes
Output current0.5A
Radio standard Wi-Fi 802.11No
Degree of protection (IP)IP20
Front built-in possibleNo
Radio standard BluetoothNo
Explosion safety category for gasNone
Appendant operation agent (Ex ia)No
Performance level according to EN ISO 13849-1None
Rack-assembly possibleYes
Supporting protocol for SERCOSNo
Short-circuit protection, outputs availableYes
Supporting protocol for INTERBUS-SafetyNo
Wall mounting/direct mountingNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supply voltage DC24 - 24V
Supporting protocol for DeviceNet SafetyNo
Type of output voltageAC/DC
Supply voltage AC 60 Hz- - -V
Permitted voltage at input19.2 - 30V
Radio standard UMTSNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Digital inputs configurableNo
Permitted voltage at output24 - 24V
SIL according to IEC 61508None
Digital outputs configurableYes
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFIsafeNo
Radio standard GSMNo
Radio standard GPRSNo
Supply voltage AC 50 Hz- - -V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

STBDDO3410K | 24VDC OUT 4PT KIT Conns,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

128.3mm

Height

13.9mm

Suitable for safety functions

Depth

70mm

Input current at signal 1

-mA

Number of HW-interfaces serial TTY

0

Voltage type of supply voltage

AC/DC

Number of digital outputs

4

Supporting protocol for DeviceNet

Supporting protocol for CAN

Time delay at signal exchange

0.56 .. 0.87ms

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for Data-Highway

Number of HW-interfaces RS-422

0

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Number of HW-interfaces other

0

Number of HW-interfaces USB

0

Supporting protocol for LON

With optical interface

Number of digital inputs

0

Supporting protocol for KNX

Number of HW-interfaces RS-485

0

Number of HW-interfaces RS-232

0

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Number of HW-interfaces parallel

0

Type of voltage (input voltage)

AC/DC

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Type of electric connection

Screw connection

Rail mounting possible

Explosion safety category for dust

None

Fieldbus connection over separate bus coupler possible

IO link master

Type of digital output

Other

Number of HW-interfaces Wireless

0

Appendant operation agent (Ex ib)

Number of interfaces PROFINET

0

System accessory

Output current

0.5A

Radio standard Wi-Fi 802.11

Degree of protection (IP)

IP20

Front built-in possible

Radio standard Bluetooth

Explosion safety category for gas

None

Appendant operation agent (Ex ia)

Performance level according to EN ISO 13849-1

None

Rack-assembly possible

Supporting protocol for SERCOS

Short-circuit protection, outputs available

Supporting protocol for INTERBUS-Safety

Wall mounting/direct mounting

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supply voltage DC

24 .. 24V

Supporting protocol for DeviceNet Safety

Type of output voltage

AC/DC

Supply voltage AC 60 Hz

- .. -V

Permitted voltage at input

19.2 .. 30V

Radio standard UMTS

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Digital inputs configurable

Permitted voltage at output

24 .. 24V

SIL according to IEC 61508

None

Digital outputs configurable

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Radio standard GSM

Radio standard GPRS

Supply voltage AC 50 Hz

- .. -V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.