Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •1 KOM
- •SCHNEIDER
Technical specifications
Suitable for safety functionsNo
Height13.9mm
Input current at signal 10.4mA
Width128.3mm
Depth70mm
Number of HW-interfaces RS-2320
Time delay at signal exchange0.55 - 0.9ms
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Number of HW-interfaces other0
Supporting protocol for Data-HighwayNo
Number of HW-interfaces USB0
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for ASINo
Number of HW-interfaces RS-4220
Short-circuit protection, outputs availableYes
With optical interfaceNo
Number of HW-interfaces serial TTY0
Supporting protocol for INTERBUSYes
Type of voltage (input voltage)DC
Output current0.25A
Supporting protocol for TCP/IPYes
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Supporting protocol for CANYes
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSYes
Number of HW-interfaces RS-4850
Explosion safety category for gasNone
Type of digital outputOther
Type of electric connectionScrew connection
Rail mounting possibleNo
Supporting protocol for DeviceNetYes
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
Appendant operation agent (Ex ib)No
Fieldbus connection over separate bus coupler possibleYes
System accessoryYes
Appendant operation agent (Ex ia)No
Explosion safety category for dustNone
Radio standard BluetoothNo
Supporting protocol for DeviceNet SafetyNo
Radio standard Wi-Fi 802.11No
Front built-in possibleNo
Performance level according to EN ISO 13849-1None
IO link masterNo
Wall mounting/direct mountingNo
Number of HW-interfaces Wireless0
Supporting protocol for AS-Interface Safety at WorkNo
Rack-assembly possibleYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Digital inputs configurableNo
Type of output voltageDC
Permitted voltage at input19.2 - 30V
Supply voltage DC24 - 24V
Supply voltage AC 60 Hz- - -V
Radio standard GSMNo
Radio standard UMTSNo
Digital outputs configurableYes
Radio standard GPRSNo
SIL according to IEC 61508None
Permitted voltage at output24 - 24V
Supply voltage AC 50 Hz- - -V
Number of digital inputs0
Number of digital outputs4
Voltage type of supply voltageDC
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user