Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth70mm
Height13.9mm
Width128.3mm
Voltage type of supply voltageDC
Number of digital outputs6
Number of digital inputs0
Time delay at signal exchange0.715 - 0.955ms
Input current at signal 10.4mA
Suitable for safety functionsNo
Supporting protocol for LONNo
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Type of voltage (input voltage)DC
Number of HW-interfaces other0
Number of HW-interfaces RS-4850
Supporting protocol for ModbusYes
Number of HW-interfaces parallel0
With optical interfaceNo
Supporting protocol for CANYes
Supporting protocol for TCP/IPYes
Number of HW-interfaces RS-2320
Supporting protocol for Data-HighwayNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSYes
Supporting protocol for ASINo
Supporting protocol for INTERBUSYes
Number of HW-interfaces industrial Ethernet0
Type of digital outputOther
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Number of HW-interfaces RS-4220
Short-circuit protection, outputs availableYes
Output current0.5A
Supporting protocol for DeviceNetYes
Appendant operation agent (Ex ia)No
Front built-in possibleNo
Rail mounting possibleNo
Explosion safety category for dustNone
Supporting protocol for SERCOSNo
Appendant operation agent (Ex ib)No
Degree of protection (IP)IP20
Explosion safety category for gasNone
Number of HW-interfaces Wireless0
Wall mounting/direct mountingNo
Radio standard BluetoothNo
System accessoryYes
Supporting protocol for INTERBUS-SafetyNo
Rack-assembly possibleYes
Number of interfaces PROFINET0
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Fieldbus connection over separate bus coupler possibleYes
Type of electric connectionScrew connection
IO link masterNo
Radio standard Wi-Fi 802.11No
Performance level according to EN ISO 13849-1None
Supporting protocol for EtherNet/IPYes
Supply voltage AC 50 Hz- - -V
Supply voltage DC24 - 24V
Permitted voltage at output24 - 24V
Radio standard UMTSNo
Type of output voltageDC
Supply voltage AC 60 Hz- - -V
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Radio standard GPRSNo
Radio standard GSMNo
Digital outputs configurableYes
Permitted voltage at input19.2 - 30V
Supporting protocol for PROFINET IONo
SIL according to IEC 61508None
Digital inputs configurableNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

STBDDO3600K | Modul Dig. 24VDC OUT 6PT Source 05,A OCP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

70mm

Height

13.9mm

Width

128.3mm

Voltage type of supply voltage

DC

Number of digital outputs

6

Number of digital inputs

0

Time delay at signal exchange

0.715 .. 0.955ms

Input current at signal 1

0.4mA

Suitable for safety functions

Supporting protocol for LON

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Type of voltage (input voltage)

DC

Number of HW-interfaces other

0

Number of HW-interfaces RS-485

0

Supporting protocol for Modbus

Number of HW-interfaces parallel

0

With optical interface

Supporting protocol for CAN

Supporting protocol for TCP/IP

Number of HW-interfaces RS-232

0

Supporting protocol for Data-Highway

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for INTERBUS

Number of HW-interfaces industrial Ethernet

0

Type of digital output

Other

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Number of HW-interfaces RS-422

0

Short-circuit protection, outputs available

Output current

0.5A

Supporting protocol for DeviceNet

Appendant operation agent (Ex ia)

Front built-in possible

Rail mounting possible

Explosion safety category for dust

None

Supporting protocol for SERCOS

Appendant operation agent (Ex ib)

Degree of protection (IP)

IP20

Explosion safety category for gas

None

Number of HW-interfaces Wireless

0

Wall mounting/direct mounting

Radio standard Bluetooth

System accessory

Supporting protocol for INTERBUS-Safety

Rack-assembly possible

Number of interfaces PROFINET

0

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Fieldbus connection over separate bus coupler possible

Type of electric connection

Screw connection

IO link master

Radio standard Wi-Fi 802.11

Performance level according to EN ISO 13849-1

None

Supporting protocol for EtherNet/IP

Supply voltage AC 50 Hz

- .. -V

Supply voltage DC

24 .. 24V

Permitted voltage at output

24 .. 24V

Radio standard UMTS

Type of output voltage

DC

Supply voltage AC 60 Hz

- .. -V

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Radio standard GPRS

Radio standard GSM

Digital outputs configurable

Permitted voltage at input

19.2 .. 30V

Supporting protocol for PROFINET IO

SIL according to IEC 61508

None

Digital inputs configurable

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.