Technical specifications

Depth70mm
Suitable for safety functionsNo
Input current at signal 10.4mA
Width128.3mm
Height13.9mm
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Time delay at signal exchange2 - 2ms
Number of HW-interfaces RS-4850
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
With optical interfaceNo
Supporting protocol for PROFIBUSYes
Number of HW-interfaces other0
Type of voltage (input voltage)DC
Number of HW-interfaces parallel0
Supporting protocol for INTERBUSYes
Supporting protocol for CANYes
Supporting protocol for ASINo
Supporting protocol for TCP/IPYes
Supporting protocol for KNXNo
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Type of electric connectionScrew connection
Explosion safety category for gasNone
Explosion safety category for dustNone
System accessoryYes
Short-circuit protection, outputs availableYes
Type of digital outputOther
Rail mounting possibleNo
Fieldbus connection over separate bus coupler possibleYes
Output current0.5A
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
Supporting protocol for INTERBUS-SafetyNo
Appendant operation agent (Ex ia)No
Front built-in possibleNo
Appendant operation agent (Ex ib)No
Number of HW-interfaces Wireless0
Radio standard Wi-Fi 802.11No
Rack-assembly possibleYes
Supporting protocol for DeviceNet SafetyNo
IO link masterNo
Performance level according to EN ISO 13849-1None
Supporting protocol for AS-Interface Safety at WorkNo
Radio standard BluetoothNo
Wall mounting/direct mountingNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Radio standard GSMNo
Supply voltage AC 50 Hz- - -V
Permitted voltage at input19.2 - 30V
Supply voltage AC 60 Hz- - -V
Radio standard GPRSNo
Digital outputs configurableYes
Permitted voltage at output24 - 24V
Type of output voltageDC
Supply voltage DC24 - 24V
Digital inputs configurableNo
Radio standard UMTSNo
SIL according to IEC 61508None
Number of digital inputs0
Number of digital outputs16
Voltage type of supply voltageDC
Degree of protection (IP)IP20