Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height13.9mm
Depth70mm
Width128.3mm
Number of HW-interfaces parallel0
Suitable for safety functionsNo
Time delay at signal exchange5.25 - 6.75ms
With optical interfaceNo
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
Number of HW-interfaces other0
Number of digital outputs2
Number of digital inputs0
Voltage type of supply voltageAC/DC
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of HW-interfaces industrial Ethernet0
Input current at signal 10.4mA
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSYes
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for INTERBUSYes
Type of voltage (input voltage)AC/DC
Supporting protocol for ASINo
Supporting protocol for DeviceNetYes
Supporting protocol for SUCONETNo
Explosion safety category for gasNone
Supporting protocol for other bus systemsNo
Type of electric connectionScrew connection
Fieldbus connection over separate bus coupler possibleYes
Output current2A
Appendant operation agent (Ex ia)No
Short-circuit protection, outputs availableNo
Appendant operation agent (Ex ib)No
Type of digital outputRelay
Explosion safety category for dustNone
Rail mounting possibleNo
System accessoryYes
Degree of protection (IP)IP20
Number of interfaces PROFINET0
Number of HW-interfaces Wireless0
Wall mounting/direct mountingNo
Rack-assembly possibleYes
IO link masterNo
Radio standard Wi-Fi 802.11No
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Radio standard BluetoothNo
Front built-in possibleNo
Performance level according to EN ISO 13849-1None
Supply voltage AC 60 Hz115 - 230V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPYes
Supply voltage AC 50 Hz115 - 230V
Permitted voltage at output24 - 230V
Type of output voltageAC/DC
SIL according to IEC 61508None
Permitted voltage at input20 - 250V
Radio standard GSMNo
Radio standard GPRSNo
Supply voltage DC24 - 24V
Radio standard UMTSNo
Digital inputs configurableNo
Digital outputs configurableYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

STBDRC3210K | Modul Dig. Relej OUT 2PT Formc 2A 24V CO

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

13.9mm

Depth

70mm

Width

128.3mm

Number of HW-interfaces parallel

0

Suitable for safety functions

Time delay at signal exchange

5.25 .. 6.75ms

With optical interface

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

Number of digital outputs

2

Number of digital inputs

0

Voltage type of supply voltage

AC/DC

Number of HW-interfaces RS-485

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces industrial Ethernet

0

Input current at signal 1

0.4mA

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for INTERBUS

Type of voltage (input voltage)

AC/DC

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Explosion safety category for gas

None

Supporting protocol for other bus systems

Type of electric connection

Screw connection

Fieldbus connection over separate bus coupler possible

Output current

2A

Appendant operation agent (Ex ia)

Short-circuit protection, outputs available

Appendant operation agent (Ex ib)

Type of digital output

Relay

Explosion safety category for dust

None

Rail mounting possible

System accessory

Degree of protection (IP)

IP20

Number of interfaces PROFINET

0

Number of HW-interfaces Wireless

0

Wall mounting/direct mounting

Rack-assembly possible

IO link master

Radio standard Wi-Fi 802.11

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Radio standard Bluetooth

Front built-in possible

Performance level according to EN ISO 13849-1

None

Supply voltage AC 60 Hz

115 .. 230V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Supply voltage AC 50 Hz

115 .. 230V

Permitted voltage at output

24 .. 230V

Type of output voltage

AC/DC

SIL according to IEC 61508

None

Permitted voltage at input

20 .. 250V

Radio standard GSM

Radio standard GPRS

Supply voltage DC

24 .. 24V

Radio standard UMTS

Digital inputs configurable

Digital outputs configurable

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.