Details
- •Programmable logic controllers PLC
- •PLC CPU-module
- •1 KOM
- •SCHNEIDER
Technical specifications
TM221C16T | PLC Compact 16IO Transistor

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Number of HW-interfaces industrial Ethernet
0
Depth
75.9mm
Number of digital inputs
9
Memory size
512kByte
Number of digital outputs
7
Width
95mm
With display
Supporting protocol for LON
Number of analogue inputs
2
Processing time (1K, binary operation)
0.2ms
Height
103.6mm
Type of memory
RAM
Suitable for safety functions
Voltage type of supply voltage
DC
Number of analogue outputs
0
Model
Compact
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces USB
1
Number of HW-interfaces RS-485
1
Number of HW-interfaces other
0
Additional program memory possible
With optical interface
Number of HW-interfaces parallel
0
Redundancy
Supporting protocol for KNX
Supporting protocol for DeviceNet
Explosion safety category for dust
None
Supporting protocol for SUCONET
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Explosion safety category for gas
None
Supporting protocol for other bus systems
Rail mounting possible
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for INTERBUS-Safety
Number of interfaces PROFINET
0
Supporting protocol for SERCOS
Appendant operation agent (Ex ib)
Appendant operation agent (Ex ia)
System accessory
Wall mounting/direct mounting
IO link master
Radio standard Wi-Fi 802.11
Supporting protocol for Foundation Fieldbus
Radio standard Bluetooth
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET CBA
Number of relay outputs
0
Front built-in possible
Performance level according to EN ISO 13849-1
None
Supporting protocol for EtherNet/IP
Number of HW-interfaces Wireless
0
Max. number of time switches
255
Supporting protocol for AS-Interface Safety at Work
Rack-assembly possible
Supporting protocol for PROFIsafe
Supply voltage AC 60 Hz
0 .. 0V
Supply voltage DC
19.2 .. 28.8V
Radio standard UMTS
Long-Term Evolution (LTE)
Radio standard GSM
Radio standard GPRS
Supporting protocol for SafetyBUS p
Supply voltage AC 50 Hz
0 .. 0V
Supporting protocol for PROFINET IO
Supporting protocol for IEC 61850 Ethernet
SIL according to IEC 61508
None
Supporting protocol for IEC 60870
Supporting protocol for DNP3