Details
- •Programmable logic controllers PLC
- •PLC CPU-module
- •1 KOM
- •SCHNEIDER
Technical specifications
TM221C40R | PLC Compact 40IO Relay

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Height
103.6mm
Width
160mm
Suitable for safety functions
Depth
75.9mm
With display
Model
Compact
Number of digital outputs
0
Number of digital inputs
24
Number of analogue inputs
2
Type of memory
RAM
Number of HW-interfaces USB
1
Supporting protocol for Modbus
Supporting protocol for INTERBUS
Additional program memory possible
Supporting protocol for LON
Supporting protocol for KNX
With optical interface
Supporting protocol for Data-Highway
Processing time (1K, binary operation)
0.2ms
Supporting protocol for TCP/IP
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces other
0
Supporting protocol for CAN
Memory size
512kByte
Supporting protocol for PROFIBUS
Number of HW-interfaces RS-232
1
Number of HW-interfaces RS-422
0
Supporting protocol for SUCONET
Number of analogue outputs
0
Supporting protocol for DeviceNet
Voltage type of supply voltage
AC
Supporting protocol for ASI
Number of HW-interfaces parallel
0
Supporting protocol for other bus systems
IO link master
Supporting protocol for INTERBUS-Safety
Rack-assembly possible
System accessory
Supporting protocol for AS-Interface Safety at Work
Rail mounting possible
Performance level according to EN ISO 13849-1
None
Explosion safety category for dust
None
Appendant operation agent (Ex ib)
Number of interfaces PROFINET
0
Radio standard Bluetooth
Wall mounting/direct mounting
Appendant operation agent (Ex ia)
Supporting protocol for SERCOS
Max. number of time switches
255
Radio standard Wi-Fi 802.11
Supporting protocol for Foundation Fieldbus
Front built-in possible
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Redundancy
Number of relay outputs
16
Explosion safety category for gas
None
Number of HW-interfaces Wireless
0
Supply voltage DC
0 .. 0V
Supporting protocol for SafetyBUS p
Long-Term Evolution (LTE)
Supply voltage AC 60 Hz
85 .. 264V
Radio standard UMTS
Supporting protocol for PROFINET IO
Supply voltage AC 50 Hz
85 .. 264V
Supporting protocol for PROFINET CBA
SIL according to IEC 61508
None
Supporting protocol for IEC 61850 Ethernet
Supporting protocol for DNP3
Radio standard GSM
Radio standard GPRS
Supporting protocol for IEC 60870
Supporting protocol for PROFIsafe