Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage DC
0 - 0V
Number of HW-interfaces industrial Ethernet
1
Supply voltage AC 50 Hz
85 - 264V
Number of HW-interfaces RS-232
1
Number of relay outputs
7
Number of HW-interfaces RS-422
0
Model
Compact
Processing time (1K, binary operation)
0.2ms
Supporting protocol for INTERBUS
No
Supporting protocol for KNX
No
Number of HW-interfaces USB
1
Supporting protocol for PROFIBUS
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Number of HW-interfaces Wireless
0
Number of interfaces PROFINET
0
Number of digital outputs
0
Supporting protocol for Modbus
Yes
Number of HW-interfaces parallel
0
Supporting protocol for TCP/IP
Yes
Number of HW-interfaces RS-485
1
Voltage type of supply voltage
AC
Supporting protocol for ASI
No
Number of digital inputs
9
Supply voltage AC 60 Hz
85 - 264V
Number of HW-interfaces other
0
With optical interface
No
Supporting protocol for CAN
No
Supporting protocol for PROFINET IO
No
Number of analogue outputs
0
Supporting protocol for EtherCAT
No
Max. number of time switches
255
Number of analogue inputs
2
Radio standard GSM
No
Radio standard 4G
No
Radio standard UMTS
No
IO link master
No
System accessory
No
Redundancy
No
Type of memory
RAM
With display
No
Additional program memory possible
Yes
Memory size
512kByte
Rail mounting possible
Yes
Wall mounting/direct mounting
Yes
Front built-in possible
No
Rack-assembly possible
No
Suitable for safety functions
No
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Performance level according to EN ISO 13849-1
None
Explosion safety category for gas
None
Explosion safety category for dust
None
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Height
103.6mm
Width
95mm
Depth
75.9mm
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for IEC 60870
No
Supporting protocol for DNP3
No
Supporting protocol for IEC 61850 Ethernet
No
Radio standard Bluetooth
No
Radio standard GPRS
No
Radio standard Wi-Fi 802.11
No
TM221CE16R

Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage DC
0 .. 0V
Number of HW-interfaces industrial Ethernet
1
Supply voltage AC 50 Hz
85 .. 264V
Number of HW-interfaces RS-232
1
Number of relay outputs
7
Number of HW-interfaces RS-422
0
Model
Compact
Processing time (1K, binary operation)
0.2ms
Supporting protocol for INTERBUS
Supporting protocol for KNX
Number of HW-interfaces USB
1
Supporting protocol for PROFIBUS
Supporting protocol for LON
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Number of HW-interfaces Wireless
0
Number of interfaces PROFINET
0
Number of digital outputs
0
Supporting protocol for Modbus
Number of HW-interfaces parallel
0
Supporting protocol for TCP/IP
Number of HW-interfaces RS-485
1
Voltage type of supply voltage
AC
Supporting protocol for ASI
Number of digital inputs
9
Supply voltage AC 60 Hz
85 .. 264V
Number of HW-interfaces other
0
With optical interface
Supporting protocol for CAN
Supporting protocol for PROFINET IO
Number of analogue outputs
0
Supporting protocol for EtherCAT
Max. number of time switches
255
Number of analogue inputs
2
Radio standard GSM
Radio standard 4G
Radio standard UMTS
IO link master
System accessory
Redundancy
Type of memory
RAM
With display
Additional program memory possible
Memory size
512kByte
Rail mounting possible
Wall mounting/direct mounting
Front built-in possible
Rack-assembly possible
Suitable for safety functions
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Performance level according to EN ISO 13849-1
None
Explosion safety category for gas
None
Explosion safety category for dust
None
Certified for UL hazardous location class I
Certified for UL hazardous location class II
Certified for UL hazardous location class III
Certified for UL hazardous location division 1
Certified for UL hazardous location division 2
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Height
103.6mm
Width
95mm
Depth
75.9mm
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for IEC 60870
Supporting protocol for DNP3
Supporting protocol for IEC 61850 Ethernet
Radio standard Bluetooth
Radio standard GPRS
Radio standard Wi-Fi 802.11