Suitable for safety functionsNo
Number of analogue inputs2
Number of analogue outputs0
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-2321
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces USB1
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Additional program memory possibleYes
Supporting protocol for TCP/IPYes
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Rail mounting possibleYes
Explosion safety category for gasNone
Explosion safety category for dustNone
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
Number of HW-interfaces Wireless0
Front built-in possibleNo
Wall mounting/direct mountingYes
Radio standard BluetoothNo
Radio standard Wi-Fi 802.11No
Max. number of time switches255
Performance level according to EN ISO 13849-1None
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supply voltage AC 60 Hz85 - 264V
SIL according to IEC 61508None
Supporting protocol for IEC 61850 EthernetNo
Supporting protocol for DNP3No
Supporting protocol for IEC 60870No
Supporting protocol for EtherCATNo
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group G (non-conductive dusts)No
Number of digital inputs9
Number of digital outputs0
Voltage type of supply voltageAC
Processing time (1K, binary operation)0.2ms
Supply voltage AC 50 Hz85 - 264V