Technical specifications

Supply voltage AC 50 Hz0 - 0V
Supply voltage AC 60 Hz0 - 0V
ModelCompact
Voltage type of supply voltageDC
Number of relay outputs0
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-2321
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces USB1
Number of HW-interfaces parallel0
Number of HW-interfaces Wireless0
Number of HW-interfaces other0
Number of interfaces PROFINET0
Number of analogue outputs0
Number of digital inputs14
Supply voltage DC19.2 - 28.8V
Number of analogue inputs2
Number of digital outputs10
Max. number of time switches255
Supporting protocol for CANNo
Supporting protocol for TCP/IPYes
With optical interfaceNo
Supporting protocol for PROFIBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Processing time (1K, binary operation)0.2ms
Supporting protocol for Data-HighwayNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Supporting protocol for ASINo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Supporting protocol for INTERBUSNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNetNo
Long-Term Evolution (LTE)No
IO link masterNo
System accessoryNo
Radio standard BluetoothNo
Supporting protocol for other bus systemsNo
Supporting protocol for IEC 61850 EthernetNo
RedundancyNo
With displayNo
Radio standard Wi-Fi 802.11No
Memory size512kByte
Type of memoryRAM
Radio standard GPRSNo
Radio standard UMTSNo
Radio standard GSMNo
Additional program memory possibleYes
Rail mounting possibleYes
Wall mounting/direct mountingYes
Rack-assembly possibleNo
Front built-in possibleNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ib)No
Appendant operation agent (Ex ia)No
Suitable for safety functionsNo
Width110mm
Explosion safety category for gasNone
Explosion safety category for dustNone
Height103.6mm
Depth75.9mm
Supporting protocol for DNP3No
Supporting protocol for IEC 60870No
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

TM221CE24T

Main Product Image

Details

  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supply voltage AC 50 Hz

0 .. 0V

Supply voltage AC 60 Hz

0 .. 0V

Model

Compact

Voltage type of supply voltage

DC

Number of relay outputs

0

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-232

1

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces USB

1

Number of HW-interfaces parallel

0

Number of HW-interfaces Wireless

0

Number of HW-interfaces other

0

Number of interfaces PROFINET

0

Number of analogue outputs

0

Number of digital inputs

14

Supply voltage DC

19.2 .. 28.8V

Number of analogue inputs

2

Number of digital outputs

10

Max. number of time switches

255

Supporting protocol for CAN

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Supporting protocol for Modbus

Processing time (1K, binary operation)

0.2ms

Supporting protocol for Data-Highway

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Supporting protocol for ASI

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Supporting protocol for INTERBUS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet

Long-Term Evolution (LTE)

IO link master

System accessory

Radio standard Bluetooth

Supporting protocol for other bus systems

Supporting protocol for IEC 61850 Ethernet

Redundancy

With display

Radio standard Wi-Fi 802.11

Memory size

512kByte

Type of memory

RAM

Radio standard GPRS

Radio standard UMTS

Radio standard GSM

Additional program memory possible

Rail mounting possible

Wall mounting/direct mounting

Rack-assembly possible

Front built-in possible

SIL according to IEC 61508

None

Performance level according to EN ISO 13849-1

None

Appendant operation agent (Ex ib)

Appendant operation agent (Ex ia)

Suitable for safety functions

Width

110mm

Explosion safety category for gas

None

Explosion safety category for dust

None

Height

103.6mm

Depth

75.9mm

Supporting protocol for DNP3

Supporting protocol for IEC 60870

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe