Details
- •Programmable logic controllers PLC
- •PLC CPU-module
- •1 KOM
- •SCHNEIDER
Technical specifications
TM221CE40T

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Width
160mm
Depth
75.9mm
Model
Compact
Suitable for safety functions
Number of analogue outputs
0
Voltage type of supply voltage
DC
With display
Number of analogue inputs
2
Number of digital inputs
24
Type of memory
RAM
Number of digital outputs
16
Height
103.6mm
Processing time (1K, binary operation)
0.2ms
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for LON
Number of HW-interfaces RS-422
0
Memory size
512kByte
Number of HW-interfaces RS-232
1
Number of HW-interfaces RS-485
1
Supporting protocol for TCP/IP
Number of HW-interfaces USB
1
Additional program memory possible
Number of HW-interfaces other
0
With optical interface
Number of HW-interfaces parallel
0
Supporting protocol for other bus systems
Supporting protocol for INTERBUS
Supporting protocol for SUCONET
Supporting protocol for CAN
Supporting protocol for DeviceNet
Supporting protocol for KNX
Supporting protocol for ASI
Supporting protocol for Data-Highway
Supporting protocol for PROFIBUS
Supporting protocol for Modbus
System accessory
Rail mounting possible
Number of interfaces PROFINET
0
Rack-assembly possible
Explosion safety category for gas
None
Radio standard Bluetooth
Appendant operation agent (Ex ia)
Redundancy
Front built-in possible
Explosion safety category for dust
None
Supporting protocol for SERCOS
Appendant operation agent (Ex ib)
Wall mounting/direct mounting
Supporting protocol for INTERBUS-Safety
Number of HW-interfaces Wireless
0
Supporting protocol for AS-Interface Safety at Work
IO link master
Supporting protocol for PROFIsafe
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET CBA
Max. number of time switches
255
Supporting protocol for Foundation Fieldbus
Supporting protocol for SafetyBUS p
Supporting protocol for PROFINET IO
Supply voltage AC 50 Hz
0 .. 0V
Radio standard Wi-Fi 802.11
Performance level according to EN ISO 13849-1
None
Number of relay outputs
0
Radio standard UMTS
SIL according to IEC 61508
None
Long-Term Evolution (LTE)
Radio standard GSM
Radio standard GPRS
Supply voltage DC
19.2 .. 28.8V
Supply voltage AC 60 Hz
0 .. 0V
Supporting protocol for DNP3
Supporting protocol for IEC 60870
Supporting protocol for IEC 61850 Ethernet