Details
- •Programmable logic controllers PLC
- •PLC CPU-module
- •1 KOM
- •SCHNEIDER
Technical specifications
TM221M16RG | PLC Modular 16IO Relay

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Voltage type of supply voltage
DC
Number of analogue outputs
0
Model
Compact
Number of digital outputs
8
With display
Number of analogue inputs
2
Suitable for safety functions
Width
70mm
Number of digital inputs
8
Height
102mm
Depth
85mm
Number of HW-interfaces RS-485
2
Memory size
512kByte
Number of HW-interfaces industrial Ethernet
0
Processing time (1K, binary operation)
0.2ms
Number of HW-interfaces RS-232
2
Number of HW-interfaces RS-422
0
Type of memory
RAM
Supporting protocol for LON
Supporting protocol for PROFIBUS
Number of HW-interfaces parallel
0
With optical interface
System accessory
Supporting protocol for Modbus
Number of HW-interfaces other
0
Supporting protocol for other bus systems
Additional program memory possible
Redundancy
Explosion safety category for dust
None
Supporting protocol for SUCONET
Explosion safety category for gas
None
Supporting protocol for DeviceNet
Rail mounting possible
Number of HW-interfaces USB
1
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Supporting protocol for ASI
Supporting protocol for KNX
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for SERCOS
Appendant operation agent (Ex ib)
Supporting protocol for INTERBUS-Safety
Appendant operation agent (Ex ia)
Number of interfaces PROFINET
0
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET IO
Rack-assembly possible
Front built-in possible
Number of HW-interfaces Wireless
0
Performance level according to EN ISO 13849-1
None
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET CBA
Number of relay outputs
8
Supporting protocol for DeviceNet Safety
Max. number of time switches
255
Wall mounting/direct mounting
Radio standard Bluetooth
IO link master
Radio standard Wi-Fi 802.11
Supporting protocol for SafetyBUS p
Supply voltage AC 50 Hz
0 .. 0V
Radio standard GPRS
Radio standard GSM
Radio standard UMTS
Supply voltage DC
19.2 .. 28.8V
Supporting protocol for PROFIsafe
Supply voltage AC 60 Hz
0 .. 0V
Long-Term Evolution (LTE)
SIL according to IEC 61508
None
Supporting protocol for DNP3
Supporting protocol for IEC 60870
Supporting protocol for IEC 61850 Ethernet