Details
- •Programmable logic controllers PLC
- •PLC CPU-module
- •1 KOM
- •SCHNEIDER
Technical specifications
TM221ME16TG | PLC Modular 16IO Ethernet Transistor

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Width
70mm
Depth
85mm
With display
Number of digital outputs
8
Voltage type of supply voltage
DC
Height
102mm
Number of analogue inputs
2
Model
Compact
Number of HW-interfaces USB
1
Processing time (1K, binary operation)
0.2ms
Number of digital inputs
8
Number of HW-interfaces parallel
0
Number of analogue outputs
0
Memory size
512kByte
Number of HW-interfaces industrial Ethernet
1
Suitable for safety functions
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
Type of memory
RAM
Supporting protocol for LON
Number of HW-interfaces RS-232
1
Supporting protocol for TCP/IP
With optical interface
Additional program memory possible
Number of HW-interfaces other
0
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for KNX
Supporting protocol for other bus systems
Supporting protocol for CAN
Explosion safety category for dust
None
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Redundancy
Explosion safety category for gas
None
Supporting protocol for INTERBUS-Safety
Number of HW-interfaces Wireless
0
Appendant operation agent (Ex ia)
Rail mounting possible
Front built-in possible
System accessory
Supporting protocol for Data-Highway
Supporting protocol for SERCOS
Appendant operation agent (Ex ib)
Number of interfaces PROFINET
0
Radio standard Bluetooth
Rack-assembly possible
Wall mounting/direct mounting
Supporting protocol for SUCONET
Number of relay outputs
0
IO link master
Radio standard Wi-Fi 802.11
Performance level according to EN ISO 13849-1
None
Max. number of time switches
255
Supporting protocol for PROFINET CBA
Supply voltage AC 60 Hz
0 .. 0V
Long-Term Evolution (LTE)
Supporting protocol for EtherNet/IP
Radio standard GSM
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SafetyBUS p
Radio standard UMTS
Supply voltage DC
19.2 .. 28.8V
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supply voltage AC 50 Hz
0 .. 0V
SIL according to IEC 61508
None
Supporting protocol for Foundation Fieldbus
Radio standard GPRS
Supporting protocol for PROFINET IO
Supporting protocol for DNP3
Supporting protocol for IEC 61850 Ethernet
Supporting protocol for IEC 60870