Technical specifications

ModelCompact
Width150mm
Height90mm
Depth95mm
Number of HW-interfaces industrial Ethernet1
Processing time (1K, binary operation)0.022ms
Number of digital inputs14
With displayNo
Suitable for safety functionsNo
Voltage type of supply voltageDC
Number of analogue outputs0
Number of HW-interfaces RS-2322
Number of digital outputs10
Supporting protocol for LONNo
Number of analogue inputs0
Number of HW-interfaces RS-4220
Type of memoryNVRAM
Memory size64000kByte
Number of HW-interfaces RS-4852
Number of HW-interfaces USB1
With optical interfaceNo
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Supporting protocol for TCP/IPYes
Additional program memory possibleYes
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Explosion safety category for dustNone
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Supporting protocol for other bus systemsNo
RedundancyNo
Explosion safety category for gasNone
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetNo
Appendant operation agent (Ex ib)No
Appendant operation agent (Ex ia)No
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
System accessoryNo
Number of interfaces PROFINET0
Rail mounting possibleYes
Number of HW-interfaces Wireless0
Front built-in possibleNo
Rack-assembly possibleNo
Wall mounting/direct mountingYes
Radio standard Wi-Fi 802.11No
Radio standard BluetoothNo
IO link masterNo
Number of relay outputs0
Max. number of time switches0
Performance level according to EN ISO 13849-1None
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Radio standard GPRSNo
Supply voltage AC 50 Hz0 - 0V
Supply voltage AC 60 Hz0 - 0V
Supporting protocol for SafetyBUS pNo
Long-Term Evolution (LTE)No
Radio standard UMTSNo
Supply voltage DC19.2 - 28.8V
Radio standard GSMNo
SIL according to IEC 61508None
Supporting protocol for IEC 60870No
Supporting protocol for DNP3No
Supporting protocol for IEC 61850 EthernetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

TM241CE24T | PLC Compact 24IO Ethernet Transistor PNP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Model

Compact

Width

150mm

Height

90mm

Depth

95mm

Number of HW-interfaces industrial Ethernet

1

Processing time (1K, binary operation)

0.022ms

Number of digital inputs

14

With display

Suitable for safety functions

Voltage type of supply voltage

DC

Number of analogue outputs

0

Number of HW-interfaces RS-232

2

Number of digital outputs

10

Supporting protocol for LON

Number of analogue inputs

0

Number of HW-interfaces RS-422

0

Type of memory

NVRAM

Memory size

64000kByte

Number of HW-interfaces RS-485

2

Number of HW-interfaces USB

1

With optical interface

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Additional program memory possible

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Explosion safety category for dust

None

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for KNX

Supporting protocol for other bus systems

Redundancy

Explosion safety category for gas

None

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Appendant operation agent (Ex ib)

Appendant operation agent (Ex ia)

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

System accessory

Number of interfaces PROFINET

0

Rail mounting possible

Number of HW-interfaces Wireless

0

Front built-in possible

Rack-assembly possible

Wall mounting/direct mounting

Radio standard Wi-Fi 802.11

Radio standard Bluetooth

IO link master

Number of relay outputs

0

Max. number of time switches

0

Performance level according to EN ISO 13849-1

None

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Radio standard GPRS

Supply voltage AC 50 Hz

0 .. 0V

Supply voltage AC 60 Hz

0 .. 0V

Supporting protocol for SafetyBUS p

Long-Term Evolution (LTE)

Radio standard UMTS

Supply voltage DC

19.2 .. 28.8V

Radio standard GSM

SIL according to IEC 61508

None

Supporting protocol for IEC 60870

Supporting protocol for DNP3

Supporting protocol for IEC 61850 Ethernet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.