Details
- •Programmable logic controllers PLC
- •PLC CPU-module
- •1 KOM
- •SCHNEIDER
Technical specifications
TM258LD42DT4L | M258 PLC ETH/SL/2PCI/42DIO/4AI

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Width
237.5mm
Height
99mm
Depth
85mm
Model
Compact
With display
Number of analogue outputs
0
Number of digital outputs
16
Suitable for safety functions
Memory size
64000kByte
Supporting protocol for LON
Number of HW-interfaces USB
2
Number of analogue inputs
4
Supporting protocol for INTERBUS
Number of digital inputs
26
Voltage type of supply voltage
AC/DC
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Number of HW-interfaces other
0
Number of HW-interfaces RS-232
1
Supporting protocol for ASI
Number of HW-interfaces parallel
0
Processing time (1K, binary operation)
0.022ms
Supporting protocol for CAN
With optical interface
Additional program memory possible
Number of HW-interfaces RS-485
1
Type of memory
NVRAM
Number of HW-interfaces RS-422
0
Appendant operation agent (Ex ia)
Explosion safety category for gas
None
Supporting protocol for SUCONET
Supporting protocol for other bus systems
System accessory
Rail mounting possible
Number of relay outputs
0
Number of HW-interfaces Wireless
0
Supporting protocol for KNX
Wall mounting/direct mounting
Supporting protocol for DeviceNet
Supporting protocol for SERCOS
Radio standard Bluetooth
Explosion safety category for dust
None
Rack-assembly possible
Number of interfaces PROFINET
0
Max. number of time switches
0
IO link master
Radio standard Wi-Fi 802.11
Supporting protocol for Modbus
Appendant operation agent (Ex ib)
Supporting protocol for Data-Highway
Front built-in possible
Supporting protocol for INTERBUS-Safety
Redundancy
Supporting protocol for SafetyBUS p
Supporting protocol for AS-Interface Safety at Work
Long-Term Evolution (LTE)
Supporting protocol for EtherNet/IP
Supporting protocol for IEC 61850 Ethernet
Supporting protocol for PROFINET IO
Supply voltage DC
24 .. 24V
Supply voltage AC 60 Hz
0 .. 0V
Supporting protocol for PROFINET CBA
Performance level according to EN ISO 13849-1
None
Supply voltage AC 50 Hz
0 .. 0V
Supporting protocol for Foundation Fieldbus
Radio standard GPRS
Supporting protocol for DNP3
Supporting protocol for PROFIsafe
Supporting protocol for DeviceNet Safety
Radio standard UMTS
Radio standard GSM
SIL according to IEC 61508
None
Supporting protocol for IEC 60870