  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supply voltage AC 50 Hz0 - 0V
Supply voltage AC 60 Hz0 - 0V
Voltage type of supply voltageAC/DC
Number of relay outputs0
Max. number of time switches0
ModelCompact
Processing time (1K, binary operation)0.022ms
Supply voltage DC24 - 24V
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2321
Number of HW-interfaces RS-4220
Number of HW-interfaces USB2
Number of HW-interfaces parallel0
Number of HW-interfaces other1
Number of analogue inputs0
Number of analogue outputs0
Number of digital outputs16
Number of HW-interfaces Wireless0
Supporting protocol for CANYes
Supporting protocol for PROFIBUSNo
With optical interfaceNo
Supporting protocol for TCP/IPYes
Number of digital inputs26
Number of interfaces PROFINET0
Supporting protocol for Data-HighwayNo
Supporting protocol for ASINo
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for Foundation FieldbusNo
Long-Term Evolution (LTE)No
Supporting protocol for PROFINET IONo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
System accessoryNo
IO link masterNo
RedundancyNo
Type of memoryNVRAM
Memory size64000kByte
With displayNo
Additional program memory possibleYes
Rail mounting possibleYes
Wall mounting/direct mountingNo
Front built-in possibleNo
Rack-assembly possibleYes
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Explosion safety category for gasNone
Explosion safety category for dustNone
Height99mm
Width175mm
Depth85mm
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Supporting protocol for IEC 60870No
Supporting protocol for IEC 61850 EthernetNo
Supporting protocol for DNP3No
Radio standard BluetoothNo
Radio standard GPRSNo
Radio standard Wi-Fi 802.11No
Radio standard GSMNo
Radio standard UMTSNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

TM258LF42DT

Main Product Image

Details

  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supply voltage AC 50 Hz

0 .. 0V

Supply voltage AC 60 Hz

0 .. 0V

Voltage type of supply voltage

AC/DC

Number of relay outputs

0

Max. number of time switches

0

Model

Compact

Processing time (1K, binary operation)

0.022ms

Supply voltage DC

24 .. 24V

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

1

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

2

Number of HW-interfaces parallel

0

Number of HW-interfaces other

1

Number of analogue inputs

0

Number of analogue outputs

0

Number of digital outputs

16

Number of HW-interfaces Wireless

0

Supporting protocol for CAN

Supporting protocol for PROFIBUS

With optical interface

Supporting protocol for TCP/IP

Number of digital inputs

26

Number of interfaces PROFINET

0

Supporting protocol for Data-Highway

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for Foundation Fieldbus

Long-Term Evolution (LTE)

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

System accessory

IO link master

Redundancy

Type of memory

NVRAM

Memory size

64000kByte

With display

Additional program memory possible

Rail mounting possible

Wall mounting/direct mounting

Front built-in possible

Rack-assembly possible

Suitable for safety functions

SIL according to IEC 61508

None

Performance level according to EN ISO 13849-1

None

Appendant operation agent (Ex ia)

Appendant operation agent (Ex ib)

Explosion safety category for gas

None

Explosion safety category for dust

None

Height

99mm

Width

175mm

Depth

85mm

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Supporting protocol for IEC 60870

Supporting protocol for IEC 61850 Ethernet

Supporting protocol for DNP3

Radio standard Bluetooth

Radio standard GPRS

Radio standard Wi-Fi 802.11

Radio standard GSM

Radio standard UMTS