TM258LF42DT | M258 PLC ETH/CAN/SL/42DIO

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Model
Compact
Width
175mm
Number of HW-interfaces RS-232
1
Memory size
64000kByte
Type of memory
NVRAM
Height
99mm
Depth
85mm
Number of HW-interfaces industrial Ethernet
1
Voltage type of supply voltage
AC/DC
Number of digital inputs
26
With display
Supporting protocol for LON
Number of analogue inputs
0
Number of analogue outputs
0
Suitable for safety functions
Processing time (1K, binary operation)
0.022ms
Number of digital outputs
16
Supporting protocol for Modbus
Supporting protocol for CAN
Supporting protocol for ASI
Number of HW-interfaces USB
2
Number of HW-interfaces RS-422
0
Supporting protocol for KNX
Additional program memory possible
Supporting protocol for PROFIBUS
Number of HW-interfaces other
1
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS
Supporting protocol for Data-Highway
Number of HW-interfaces RS-485
1
Number of HW-interfaces parallel
0
With optical interface
Supporting protocol for other bus systems
Redundancy
Appendant operation agent (Ex ib)
Rail mounting possible
Explosion safety category for gas
None
Appendant operation agent (Ex ia)
Supporting protocol for DeviceNet
Explosion safety category for dust
None
Supporting protocol for SUCONET
System accessory
Radio standard Bluetooth
Rack-assembly possible
Radio standard Wi-Fi 802.11
IO link master
Supporting protocol for SERCOS
Number of HW-interfaces Wireless
0
Number of interfaces PROFINET
0
Front built-in possible
Wall mounting/direct mounting
Number of relay outputs
0
Supporting protocol for INTERBUS-Safety
Radio standard GPRS
Performance level according to EN ISO 13849-1
None
Supply voltage AC 50 Hz
0 .. 0V
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SafetyBUS p
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Max. number of time switches
0
Supporting protocol for PROFIsafe
Supply voltage DC
24 .. 24V
Supply voltage AC 60 Hz
0 .. 0V
Radio standard GSM
Radio standard UMTS
Supporting protocol for IEC 60870
Supporting protocol for DNP3
Long-Term Evolution (LTE)
SIL according to IEC 61508
None
Supporting protocol for IEC 61850 Ethernet