  • SCHNEIDER

Technical specifications

Supply voltage AC 50 Hz0 - 0V
Supply voltage AC 60 Hz0 - 0V
Supply voltage DC24 - 24V
Number of relay outputs0
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2321
Number of HW-interfaces industrial Ethernet1
Processing time (1K, binary operation)0.022ms
Number of digital inputs26
Number of interfaces PROFINET0
Voltage type of supply voltageAC/DC
Number of HW-interfaces RS-4220
Number of HW-interfaces USB2
Number of HW-interfaces parallel0
Number of analogue inputs4
Supporting protocol for TCP/IPYes
Max. number of time switches0
Number of analogue outputs0
With optical interfaceNo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Supporting protocol for LONNo
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Supporting protocol for PROFINET CBANo
Supporting protocol for Data-HighwayNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPYes
ModelCompact
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for CANYes
Supporting protocol for KNXNo
Number of HW-interfaces other1
Supporting protocol for SUCONETNo
Number of digital outputs16
Supporting protocol for AS-Interface Safety at WorkNo
Number of HW-interfaces Wireless0
Supporting protocol for INTERBUS-SafetyNo
Long-Term Evolution (LTE)No
IO link masterNo
System accessoryNo
RedundancyNo
With displayNo
Type of memoryNVRAM
Additional program memory possibleYes
Rail mounting possibleYes
Memory size64000kByte
Rack-assembly possibleYes
Front built-in possibleNo
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Wall mounting/direct mountingNo
Explosion safety category for gasNone
Explosion safety category for dustNone
Width237.5mm
Height99mm
Depth85mm
Supporting protocol for SafetyBUS pNo
Supporting protocol for IEC 60870No
Radio standard Wi-Fi 802.11No
Radio standard GSMNo
Supporting protocol for IEC 61850 EthernetNo
Supporting protocol for PROFIsafeNo
Supporting protocol for other bus systemsNo
Radio standard GPRSNo
Supporting protocol for DNP3No
Radio standard UMTSNo
Radio standard BluetoothNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

TM258LF42DT4L

Main Product Image

Details

  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supply voltage AC 50 Hz

0 .. 0V

Supply voltage AC 60 Hz

0 .. 0V

Supply voltage DC

24 .. 24V

Number of relay outputs

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

1

Number of HW-interfaces industrial Ethernet

1

Processing time (1K, binary operation)

0.022ms

Number of digital inputs

26

Number of interfaces PROFINET

0

Voltage type of supply voltage

AC/DC

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

2

Number of HW-interfaces parallel

0

Number of analogue inputs

4

Supporting protocol for TCP/IP

Max. number of time switches

0

Number of analogue outputs

0

With optical interface

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for LON

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for PROFINET CBA

Supporting protocol for Data-Highway

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Model

Compact

Supporting protocol for DeviceNet Safety

Supporting protocol for CAN

Supporting protocol for KNX

Number of HW-interfaces other

1

Supporting protocol for SUCONET

Number of digital outputs

16

Supporting protocol for AS-Interface Safety at Work

Number of HW-interfaces Wireless

0

Supporting protocol for INTERBUS-Safety

Long-Term Evolution (LTE)

IO link master

System accessory

Redundancy

With display

Type of memory

NVRAM

Additional program memory possible

Rail mounting possible

Memory size

64000kByte

Rack-assembly possible

Front built-in possible

Suitable for safety functions

SIL according to IEC 61508

None

Performance level according to EN ISO 13849-1

None

Appendant operation agent (Ex ia)

Appendant operation agent (Ex ib)

Wall mounting/direct mounting

Explosion safety category for gas

None

Explosion safety category for dust

None

Width

237.5mm

Height

99mm

Depth

85mm

Supporting protocol for SafetyBUS p

Supporting protocol for IEC 60870

Radio standard Wi-Fi 802.11

Radio standard GSM

Supporting protocol for IEC 61850 Ethernet

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Radio standard GPRS

Supporting protocol for DNP3

Radio standard UMTS

Radio standard Bluetooth

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.