Aleta.hr
Announcement

Registration is currently available to business customers only (B2B).

Main Product Image

TM258LF42DT4L | M258 PLC ETH/CAN/SL/2PCI/42DIO/4AI

Code: 1714746

ManufacturerSchneider Electric
Catalog numberTM258LF42DT4L
TypeTM258LF42DT4L
EAN code3595864074337

Details

  • •Programmable logic controllers PLC
  • •PLC CPU-module
  • •Minimum order quantity: 1 pcs
  • •SCHNEIDER

Technical specifications

With displayNo
Height99mm
ModelCompact
Width237.5mm
Suitable for safety functionsNo
Depth85mm
Type of memoryNVRAM
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-4220
Memory size64000kByte
Number of HW-interfaces RS-4851
Number of analogue inputs4
Supporting protocol for LONNo
Number of analogue outputs0
Number of HW-interfaces RS-2321
Number of HW-interfaces USB2
Number of HW-interfaces parallel0
With optical interfaceNo
Number of HW-interfaces other1
Supporting protocol for PROFIBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Supporting protocol for CANYes
Supporting protocol for TCP/IPYes
Additional program memory possibleYes
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
RedundancyNo
Rack-assembly possibleYes
System accessoryNo
Supporting protocol for SUCONETNo
Explosion safety category for gasNone
Number of interfaces PROFINET0
Supporting protocol for other bus systemsNo
Front built-in possibleNo
Rail mounting possibleYes
Supporting protocol for SERCOSNo
Appendant operation agent (Ex ia)No
Explosion safety category for dustNone
Appendant operation agent (Ex ib)No
Number of HW-interfaces Wireless0
Performance level according to EN ISO 13849-1None
Supporting protocol for AS-Interface Safety at WorkNo
Max. number of time switches0
Number of relay outputs0
Radio standard Wi-Fi 802.11No
Wall mounting/direct mountingNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
IO link masterNo
Radio standard BluetoothNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Radio standard GSMNo
Radio standard GPRSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supply voltage AC 60 Hz0 - 0V
Supporting protocol for Foundation FieldbusNo
Radio standard UMTSNo
Supporting protocol for IEC 61850 EthernetNo
Supporting protocol for DNP3No
Supporting protocol for IEC 60870No
Long-Term Evolution (LTE)No
SIL according to IEC 61508None
Number of digital inputs26
Number of digital outputs16
Voltage type of supply voltageAC/DC
Processing time (1K, binary operation)0.022ms
Supply voltage AC 50 Hz0 - 0V
Supply voltage DC24 - 24V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as