Technical specifications
TM258LF66DT4L | M258 PLC ETH/CAN/SL/2PCI/66DIO/4AI

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Number of analogue outputs
0
Model
Compact
Processing time (1K, binary operation)
0.022ms
Number of digital inputs
38
Number of analogue inputs
4
Width
262.5mm
Suitable for safety functions
Type of memory
NVRAM
Depth
85mm
Memory size
64000kByte
Supporting protocol for LON
Height
99mm
Number of digital outputs
28
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
With display
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces RS-232
1
Voltage type of supply voltage
AC/DC
Number of HW-interfaces parallel
0
Number of HW-interfaces other
1
Number of HW-interfaces USB
2
With optical interface
Supporting protocol for KNX
Supporting protocol for INTERBUS
Redundancy
Explosion safety category for dust
None
Supporting protocol for ASI
Rail mounting possible
Supporting protocol for CAN
Supporting protocol for SUCONET
Explosion safety category for gas
None
Supporting protocol for SERCOS
Appendant operation agent (Ex ia)
Supporting protocol for PROFIBUS
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Additional program memory possible
Supporting protocol for other bus systems
System accessory
Appendant operation agent (Ex ib)
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS-Safety
Supporting protocol for TCP/IP
Number of interfaces PROFINET
0
Number of HW-interfaces Wireless
0
Front built-in possible
Rack-assembly possible
Wall mounting/direct mounting
Radio standard Bluetooth
Performance level according to EN ISO 13849-1
None
Radio standard Wi-Fi 802.11
IO link master
Supporting protocol for EtherNet/IP
Supporting protocol for PROFIsafe
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET IO
Supply voltage AC 50 Hz
0 .. 0V
Supply voltage AC 60 Hz
0 .. 0V
Supporting protocol for SafetyBUS p
Max. number of time switches
0
Number of relay outputs
0
Supporting protocol for DeviceNet Safety
Supply voltage DC
24 .. 24V
Supporting protocol for AS-Interface Safety at Work
Long-Term Evolution (LTE)
Radio standard GSM
Supporting protocol for DNP3
SIL according to IEC 61508
None
Supporting protocol for IEC 61850 Ethernet
Radio standard GPRS
Radio standard UMTS
Supporting protocol for IEC 60870