Details
- Low-voltage control systems
- Switch disconnector (AC)
- 1 KOM
- SCHNEIDER
Technical specifications
Type of control element
None
Switching power at 400 V
-kW
Version as reversing switch
No
Version as maintenance-/service switch
No
Version as main switch
No
Version as emergency stop installation
No
Version as safety switch
No
Number of switches
1
Rated operating voltage
690 - 690V
Motor drive optional
No
Voltage release optional
No
Number of auxiliary contacts as change-over contact
0
Rated permanent current Iu
25A
Rated operation power at AC-23, 400 V
7.5kW
Type of electrical connection of main circuit
Screw connection
Rated permanent current at AC-23, 400 V
14.5A
Suitable for distribution board installation
No
Device construction
Built-in device fixed built-in technique
Rated short-time withstand current lcw
0.3kA
Suitable for front mounting 4-hole
Yes
Number of auxiliary contacts as normally open contact
0
Max. rated operation voltage Ue AC
690V
Motor drive integrated
No
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Rated permanent current at AC-21, 400 V
25A
With pre-assembled cabling
No
Interlockable
No
Rated operation power at AC-3, 400 V
5.5kW
Conditioned rated short-circuit current Iq
10kA
Suitable for intermediate mounting
No
Suitable for front mounting centre
Yes
Degree of protection (IP), front side
IP20
Height
74mm
Width
55mm
Depth
60mm
V0

Details
- Low-voltage control systems
- Switch disconnector (AC)
- 1 KOM
- SCHNEIDER
Technical specifications
Type of control element
None
Switching power at 400 V
-kW
Version as reversing switch
Version as maintenance-/service switch
Version as main switch
Version as emergency stop installation
Version as safety switch
Number of switches
1
Rated operating voltage
690 .. 690V
Motor drive optional
Voltage release optional
Number of auxiliary contacts as change-over contact
0
Rated permanent current Iu
25A
Rated operation power at AC-23, 400 V
7.5kW
Type of electrical connection of main circuit
Screw connection
Rated permanent current at AC-23, 400 V
14.5A
Suitable for distribution board installation
Device construction
Built-in device fixed built-in technique
Rated short-time withstand current lcw
0.3kA
Suitable for front mounting 4-hole
Number of auxiliary contacts as normally open contact
0
Max. rated operation voltage Ue AC
690V
Motor drive integrated
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Rated permanent current at AC-21, 400 V
25A
With pre-assembled cabling
Interlockable
Rated operation power at AC-3, 400 V
5.5kW
Conditioned rated short-circuit current Iq
10kA
Suitable for intermediate mounting
Suitable for front mounting centre
Degree of protection (IP), front side
IP20
Height
74mm
Width
55mm
Depth
60mm
We use cookies to enhance your experience.