Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • SCHNEIDER

Technical specifications

Switching power at 400 V-kW
Version as main switchYes
Number of switches1
Max. rated operation voltage Ue AC690V
Version as maintenance-/service switchYes
Version as safety switchNo
Version as emergency stop installationNo
Rated operating voltage690 - 690V
Version as reversing switchNo
Rated operation power at AC-3, 400 V3kW
Number of auxiliary contacts as normally open contact0
Conditioned rated short-circuit current Iq10kA
Rated short-time withstand current lcw0.3kA
Rated permanent current Iu12A
Type of electrical connection of main circuitScrew connection
Rated operation power at AC-23, 400 V4kW
Degree of protection (IP), front sideIP65
Suitable for front mounting centreNo
Suitable for distribution board installationNo
Suitable for intermediate mountingNo
Motor drive integratedNo
Colour control elementBlack
Motor drive optionalNo
Suitable for floor mountingNo
InterlockableYes
Number of auxiliary contacts as normally closed contact0
Voltage release optionalNo
Device constructionBuilt-in device fixed built-in technique
Type of control elementShort thumb-grip
Suitable for front mounting 4-holeYes
Number of auxiliary contacts as change-over contact0
Rated permanent current at AC-23, 400 V8.1A
Number of poles3
Rated permanent current at AC-21, 400 V12A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

VBF02

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • SCHNEIDER

Technical specifications

Switching power at 400 V

-kW

Version as main switch

Number of switches

1

Max. rated operation voltage Ue AC

690V

Version as maintenance-/service switch

Version as safety switch

Version as emergency stop installation

Rated operating voltage

690 .. 690V

Version as reversing switch

Rated operation power at AC-3, 400 V

3kW

Number of auxiliary contacts as normally open contact

0

Conditioned rated short-circuit current Iq

10kA

Rated short-time withstand current lcw

0.3kA

Rated permanent current Iu

12A

Type of electrical connection of main circuit

Screw connection

Rated operation power at AC-23, 400 V

4kW

Degree of protection (IP), front side

IP65

Suitable for front mounting centre

Suitable for distribution board installation

Suitable for intermediate mounting

Motor drive integrated

Colour control element

Black

Motor drive optional

Suitable for floor mounting

Interlockable

Number of auxiliary contacts as normally closed contact

0

Voltage release optional

Device construction

Built-in device fixed built-in technique

Type of control element

Short thumb-grip

Suitable for front mounting 4-hole

Number of auxiliary contacts as change-over contact

0

Rated permanent current at AC-23, 400 V

8.1A

Number of poles

3

Rated permanent current at AC-21, 400 V

12A