Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Switching power at 400 V
-kW
Version as main switch
Yes
Version as safety switch
No
Version as reversing switch
No
Rated operation power at AC-3, 400 V
30kW
Rated short-time withstand current lcw
1.5kA
Version as maintenance-/service switch
No
Rated permanent current at AC-23, 400 V
68.5A
Number of auxiliary contacts as normally closed contact
0
Version as emergency stop installation
Yes
Number of poles
3
Motor drive optional
No
Rated operation power at AC-23, 400 V
37kW
Number of switches
1
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Conditioned rated short-circuit current Iq
10kA
Suitable for floor mounting
No
Motor drive integrated
No
Suitable for distribution board installation
No
Device construction
Built-in device fixed built-in technique
Suitable for front mounting centre
No
Suitable for intermediate mounting
No
Colour control element
Red
Voltage release optional
No
Suitable for front mounting 4-hole
Yes
Rated operating voltage
690 - 690V
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-21, 400 V
125A
Rated permanent current Iu
125A
Interlockable
Yes
Type of electrical connection of main circuit
Screw connection
Type of control element
Door coupling rotary drive
Degree of protection (IP), front side
IP65
VCCF5

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Switching power at 400 V
-kW
Version as main switch
Version as safety switch
Version as reversing switch
Rated operation power at AC-3, 400 V
30kW
Rated short-time withstand current lcw
1.5kA
Version as maintenance-/service switch
Rated permanent current at AC-23, 400 V
68.5A
Number of auxiliary contacts as normally closed contact
0
Version as emergency stop installation
Number of poles
3
Motor drive optional
Rated operation power at AC-23, 400 V
37kW
Number of switches
1
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Conditioned rated short-circuit current Iq
10kA
Suitable for floor mounting
Motor drive integrated
Suitable for distribution board installation
Device construction
Built-in device fixed built-in technique
Suitable for front mounting centre
Suitable for intermediate mounting
Colour control element
Red
Voltage release optional
Suitable for front mounting 4-hole
Rated operating voltage
690 .. 690V
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-21, 400 V
125A
Rated permanent current Iu
125A
Interlockable
Type of electrical connection of main circuit
Screw connection
Type of control element
Door coupling rotary drive
Degree of protection (IP), front side
IP65
We use cookies to enhance your experience.