Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • SCHNEIDER

Technical specifications

Switching power at 400 V-kW
Version as main switchYes
Version as maintenance-/service switchNo
Version as reversing switchNo
Number of switches1
Max. rated operation voltage Ue AC690V
Version as safety switchNo
Rated permanent current at AC-23, 400 V83A
Number of poles3
Rated operation power at AC-23, 400 V45kW
Rated permanent current Iu175A
Number of auxiliary contacts as normally open contact0
Voltage release optionalNo
Rated short-time withstand current lcw2.1kA
Rated operating voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Suitable for front mounting 4-holeYes
Motor drive integratedNo
Type of control elementDoor coupling rotary drive
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Colour control elementRed
Suitable for floor mountingNo
Rated permanent current at AC-21, 400 V160A
Type of electrical connection of main circuitScrew connection
Motor drive optionalNo
InterlockableYes
Suitable for distribution board installationNo
Suitable for front mounting centreNo
Degree of protection (IP), front sideIP65
Conditioned rated short-circuit current Iq10kA
Rated operation power at AC-3, 400 V37kW
Suitable for intermediate mountingNo
Version as emergency stop installationYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

VCCF6

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • SCHNEIDER

Technical specifications

Switching power at 400 V

-kW

Version as main switch

Version as maintenance-/service switch

Version as reversing switch

Number of switches

1

Max. rated operation voltage Ue AC

690V

Version as safety switch

Rated permanent current at AC-23, 400 V

83A

Number of poles

3

Rated operation power at AC-23, 400 V

45kW

Rated permanent current Iu

175A

Number of auxiliary contacts as normally open contact

0

Voltage release optional

Rated short-time withstand current lcw

2.1kA

Rated operating voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Suitable for front mounting 4-hole

Motor drive integrated

Type of control element

Door coupling rotary drive

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Colour control element

Red

Suitable for floor mounting

Rated permanent current at AC-21, 400 V

160A

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Interlockable

Suitable for distribution board installation

Suitable for front mounting centre

Degree of protection (IP), front side

IP65

Conditioned rated short-circuit current Iq

10kA

Rated operation power at AC-3, 400 V

37kW

Suitable for intermediate mounting

Version as emergency stop installation

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.