Aleta.hr
Main Product Image

XCKD2110M12

Code: 1718145

ManufacturerSchneider
Catalog numberXCKD2110M12
EAN code3389110197716

Details

  • Sensors
  • End switch
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated operation current Ie at AC-15, 230 V3A
Suitable for safety functionsNo
Material housingMetal
Rated operation current Ie at DC-13, 230 V0.27A
With status indicationNo
Coating housingOther
Switching functionQuick-break switch
Explosion safety category for gasNone
Type of interface for safety communicationNone
Type of electric connectionConnector M12
Type of control elementPlunger
Explosion safety category for dustNone
Construction type housingCuboid
Forced openingYes
Degree of protection (IP)IP66/IP67
Type of interfaceNone
Output electronicNo
Number of safety auxiliary contacts0
Diameter sensor0mm
Width sensor31mm
Rated operation current Ie at DC-13, 125 V0A
Rated operation current Ie at AC-15, 24 V0A
Height of sensor65mm
Rated operation current Ie at DC-13, 24 V0A
Rated operation current Ie at AC-15, 125 V0A
Length of sensor30mm
Switching function latchingNo
Housing according to normDIN EN 50047
Number of contacts as normally closed contact1
Number of contacts as normally open contact1
Number of contacts as change-over contact0
Ambient temperature during operating-25 - 70°C
Alignment of the control elementOther
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XCKD2110M12

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • End switch
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated operation current Ie at AC-15, 230 V

3A

Suitable for safety functions

Material housing

Metal

Rated operation current Ie at DC-13, 230 V

0.27A

With status indication

Coating housing

Other

Switching function

Quick-break switch

Explosion safety category for gas

None

Type of interface for safety communication

None

Type of electric connection

Connector M12

Type of control element

Plunger

Explosion safety category for dust

None

Construction type housing

Cuboid

Forced opening

Degree of protection (IP)

IP66/IP67

Type of interface

None

Output electronic

Number of safety auxiliary contacts

0

Diameter sensor

0mm

Width sensor

31mm

Rated operation current Ie at DC-13, 125 V

0A

Rated operation current Ie at AC-15, 24 V

0A

Height of sensor

65mm

Rated operation current Ie at DC-13, 24 V

0A

Rated operation current Ie at AC-15, 125 V

0A

Length of sensor

30mm

Switching function latching

Housing according to norm

DIN EN 50047

Number of contacts as normally closed contact

1

Number of contacts as normally open contact

1

Number of contacts as change-over contact

0

Ambient temperature during operating

-25 .. 70°C

Alignment of the control element

Other

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.