Aleta.hr
Main Product Image

XCKD2110P16

Code: 1718146

ManufacturerSchneider
Catalog numberXCKD2110P16
EAN code3389110196863

Details

  • Sensors
  • End switch
  • 1 KOM
  • SCHNEIDER

Technical specifications

Suitable for safety functionsNo
Rated operation current Ie at AC-15, 230 V3A
Switching functionQuick-break switch
Material housingMetal
Rated operation current Ie at DC-13, 230 V0.27A
Type of electric connectionCable entry metrical
With status indicationNo
Type of interface for safety communicationNone
Coating housingOther
Height of sensor65mm
Explosion safety category for gasNone
Output electronicNo
Width sensor31mm
Construction type housingCuboid
Explosion safety category for dustNone
Type of control elementPlunger
Rated operation current Ie at AC-15, 125 V0A
Number of safety auxiliary contacts0
Switching function latchingNo
Rated operation current Ie at DC-13, 125 V0A
Ambient temperature during operating-25 - 70°C
Length of sensor30mm
Rated operation current Ie at AC-15, 24 V0A
Forced openingYes
Diameter sensor0mm
Type of interfaceNone
Rated operation current Ie at DC-13, 24 V0A
Degree of protection (IP)IP66/IP67
Number of contacts as normally open contact1
Number of contacts as change-over contact0
Alignment of the control elementOther
Housing according to normDIN EN 50047
Number of contacts as normally closed contact1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XCKD2110P16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • End switch
  • 1 KOM
  • SCHNEIDER

Technical specifications

Suitable for safety functions

Rated operation current Ie at AC-15, 230 V

3A

Switching function

Quick-break switch

Material housing

Metal

Rated operation current Ie at DC-13, 230 V

0.27A

Type of electric connection

Cable entry metrical

With status indication

Type of interface for safety communication

None

Coating housing

Other

Height of sensor

65mm

Explosion safety category for gas

None

Output electronic

Width sensor

31mm

Construction type housing

Cuboid

Explosion safety category for dust

None

Type of control element

Plunger

Rated operation current Ie at AC-15, 125 V

0A

Number of safety auxiliary contacts

0

Switching function latching

Rated operation current Ie at DC-13, 125 V

0A

Ambient temperature during operating

-25 .. 70°C

Length of sensor

30mm

Rated operation current Ie at AC-15, 24 V

0A

Forced opening

Diameter sensor

0mm

Type of interface

None

Rated operation current Ie at DC-13, 24 V

0A

Degree of protection (IP)

IP66/IP67

Number of contacts as normally open contact

1

Number of contacts as change-over contact

0

Alignment of the control element

Other

Housing according to norm

DIN EN 50047

Number of contacts as normally closed contact

1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.