Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Length of sensor
30mm
Switching function
Other
Alignment of the control element
Other
Degree of protection (IP)
IP65
Width sensor
30mm
Height of sensor
75mm
Rated operation current Ie at DC-13, 230 V
0.1A
Suitable for safety functions
No
Rated operation current Ie at AC-15, 230 V
3A
Number of contacts as change-over contact
0
Type of interface
None
Type of control element
Plunger
Number of safety auxiliary contacts
0
Construction type housing
Cuboid
Output electronic
No
Type of interface for safety communication
None
Type of electric connection
Cable entry metrical
Number of contacts as normally closed contact
1
Switching function latching
No
Material housing
Plastic
Forced opening
Yes
Ambient temperature during operating
-25 - 70°C
Coating housing
Other
Explosion safety category for gas
None
With status indication
No
Explosion safety category for dust
None
Number of contacts as normally open contact
1
From same serie
XCKN2110P20

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Length of sensor
30mm
Switching function
Other
Alignment of the control element
Other
Degree of protection (IP)
IP65
Width sensor
30mm
Height of sensor
75mm
Rated operation current Ie at DC-13, 230 V
0.1A
Suitable for safety functions
Rated operation current Ie at AC-15, 230 V
3A
Number of contacts as change-over contact
0
Type of interface
None
Type of control element
Plunger
Number of safety auxiliary contacts
0
Construction type housing
Cuboid
Output electronic
Type of interface for safety communication
None
Type of electric connection
Cable entry metrical
Number of contacts as normally closed contact
1
Switching function latching
Material housing
Plastic
Forced opening
Ambient temperature during operating
-25 .. 70°C
Coating housing
Other
Explosion safety category for gas
None
With status indication
Explosion safety category for dust
None
Number of contacts as normally open contact
1
From same serie