Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Height of sensor
50mm
Width sensor
30mm
Output electronic
No
Type of interface for safety communication
None
Rated operation current Ie at AC-15, 230 V
3A
Number of safety auxiliary contacts
0
Number of contacts as normally open contact
1
Forced opening
Yes
Switching function
Quick-break switch
Material housing
Metal
Rated operation current Ie at DC-13, 230 V
0.22A
Switching function latching
No
Type of control element
Roller lever
Coating housing
Other
Alignment of the control element
Other
With status indication
No
Type of electric connection
Connector M12
Explosion safety category for gas
None
Number of contacts as normally closed contact
1
Ambient temperature during operating
-25 - 70°C
Explosion safety category for dust
None
Suitable for safety functions
No
Length of sensor
16mm
Construction type housing
Other
Degree of protection (IP)
IP66/IP67
Number of contacts as change-over contact
0
Type of interface
None
From same serie
XCMD2115C12

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Height of sensor
50mm
Width sensor
30mm
Output electronic
Type of interface for safety communication
None
Rated operation current Ie at AC-15, 230 V
3A
Number of safety auxiliary contacts
0
Number of contacts as normally open contact
1
Forced opening
Switching function
Quick-break switch
Material housing
Metal
Rated operation current Ie at DC-13, 230 V
0.22A
Switching function latching
Type of control element
Roller lever
Coating housing
Other
Alignment of the control element
Other
With status indication
Type of electric connection
Connector M12
Explosion safety category for gas
None
Number of contacts as normally closed contact
1
Ambient temperature during operating
-25 .. 70°C
Explosion safety category for dust
None
Suitable for safety functions
Length of sensor
16mm
Construction type housing
Other
Degree of protection (IP)
IP66/IP67
Number of contacts as change-over contact
0
Type of interface
None
From same serie
We use cookies to enhance your experience.