Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Max. operation pressure
200000hPa
Max. test pressure
360bar
Bursting pressure
720bar
Connection
Internal thread cylindrical BSPP-G (ISO 228-1)
Rated voltage Ue at AC 50 Hz
120 - 240V
Initial value measuring range pressure
0Pa
Rated operation power at AC-3, 400 V
0kW
Switching capacity at AC-3, 240 V
0kA
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electric connection
Other
Rated operation current Ie at AC-1, 400 V
0A
Number of normally open contacts as main contact
0
Suitable as limiter
Yes
Number of normally closed contacts as main contact
0
Suitable as guard
Yes
With manual on/off switch
No
Engaging pressure
10 - 160bar
Initial setting
10000 - 160000hPa
Max. operating pressure
160000hPa
Pressure-switching differential
18bar
Switch off pressure
4.5 - 142bar
Thread size
1/4 inch
End value measuring range pressure
0Pa
Number of auxiliary contacts as change-over contact
1
Rated voltage Ue at AC 60 Hz
120 - 240V
Rated voltage Ue at DC
250 - 250V
Rated operation current Ie at AC-3, 400 V
0A
Adjustable current range
0 - 0A
With hand operation
No
Suitable as 2-point controller
No
End setting
4500 - 142000hPa
Degree of protection (IP)
IP65
Electronic version
No
Depth
75mm
Height
113mm
Width
35mm
Degree of protection (NEMA)
Other
Explosion-proof
No
Medium temperature
0 - 160°C
With display
No
From same serie
XMLA160N2C11

Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Max. operation pressure
200000hPa
Max. test pressure
360bar
Bursting pressure
720bar
Connection
Internal thread cylindrical BSPP-G (ISO 228-1)
Rated voltage Ue at AC 50 Hz
120 .. 240V
Initial value measuring range pressure
0Pa
Rated operation power at AC-3, 400 V
0kW
Switching capacity at AC-3, 240 V
0kA
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electric connection
Other
Rated operation current Ie at AC-1, 400 V
0A
Number of normally open contacts as main contact
0
Suitable as limiter
Number of normally closed contacts as main contact
0
Suitable as guard
With manual on/off switch
Engaging pressure
10 .. 160bar
Initial setting
10000 .. 160000hPa
Max. operating pressure
160000hPa
Pressure-switching differential
18bar
Switch off pressure
4.5 .. 142bar
Thread size
1/4 inch
End value measuring range pressure
0Pa
Number of auxiliary contacts as change-over contact
1
Rated voltage Ue at AC 60 Hz
120 .. 240V
Rated voltage Ue at DC
250 .. 250V
Rated operation current Ie at AC-3, 400 V
0A
Adjustable current range
0 .. 0A
With hand operation
Suitable as 2-point controller
End setting
4500 .. 142000hPa
Degree of protection (IP)
IP65
Electronic version
Depth
75mm
Height
113mm
Width
35mm
Degree of protection (NEMA)
Other
Explosion-proof
Medium temperature
0 .. 160°C
With display
From same serie