Aleta.hr

Details

  • Low-voltage industrial components
  • Pressure switch
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustable current range0 - 0A
Max. operation pressure5000hPa
Suitable as 2-point controllerNo
Max. test pressure9bar
Rated voltage Ue at AC 60 Hz120 - 240V
Rated operation current Ie at AC-1, 400 V0A
Rated operation power at AC-3, 400 V0kW
Initial setting-760 - -40hPa
Switching capacity at AC-3, 240 V0kA
With hand operationNo
Number of normally open contacts as main contact0
Thread size1/4 inch
Width35mm
Number of normally closed contacts as main contact0
Electronic versionNo
Suitable as limiterYes
Suitable as guardYes
Degree of protection (NEMA)Other
Type of electric connectionScrew connection
Engaging pressure-0.76 - -0.04bar
Rated voltage Ue at AC 50 Hz120 - 240V
ConnectionInternal thread cylindrical BSPP-G (ISO 228-1)
Medium temperature0 - 70°C
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact1
Bursting pressure18bar
End value measuring range pressure0Pa
Rated operation current Ie at AC-3, 400 V0A
With manual on/off switchNo
Depth75mm
Initial value measuring range pressure0Pa
Pressure-switching differential0.24bar
Rated voltage Ue at DC250 - 250V
Degree of protection (IP)IP66
Max. operating pressure-40hPa
End setting-1000 - -280hPa
Explosion-proofNo
Number of auxiliary contacts as normally closed contact0
Switch off pressure-1 - -0.28bar
With displayNo
Height113mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XMLAM01V2S11

Main Product Image

Details

  • Low-voltage industrial components
  • Pressure switch
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustable current range

0 .. 0A

Max. operation pressure

5000hPa

Suitable as 2-point controller

Max. test pressure

9bar

Rated voltage Ue at AC 60 Hz

120 .. 240V

Rated operation current Ie at AC-1, 400 V

0A

Rated operation power at AC-3, 400 V

0kW

Initial setting

-760 .. -40hPa

Switching capacity at AC-3, 240 V

0kA

With hand operation

Number of normally open contacts as main contact

0

Thread size

1/4 inch

Width

35mm

Number of normally closed contacts as main contact

0

Electronic version

Suitable as limiter

Suitable as guard

Degree of protection (NEMA)

Other

Type of electric connection

Screw connection

Engaging pressure

-0.76 .. -0.04bar

Rated voltage Ue at AC 50 Hz

120 .. 240V

Connection

Internal thread cylindrical BSPP-G (ISO 228-1)

Medium temperature

0 .. 70°C

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

1

Bursting pressure

18bar

End value measuring range pressure

0Pa

Rated operation current Ie at AC-3, 400 V

0A

With manual on/off switch

Depth

75mm

Initial value measuring range pressure

0Pa

Pressure-switching differential

0.24bar

Rated voltage Ue at DC

250 .. 250V

Degree of protection (IP)

IP66

Max. operating pressure

-40hPa

End setting

-1000 .. -280hPa

Explosion-proof

Number of auxiliary contacts as normally closed contact

0

Switch off pressure

-1 .. -0.28bar

With display

Height

113mm

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.