Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Rated voltage Ue at DC
- - -V
Adjustable current range
- - -A
Max. operation pressure
12000hPa
Max. test pressure
-bar
Switching capacity at AC-3, 240 V
-kA
Type of pressure connection
G 3/8 inch
Switch off pressure
0.3 - 10.3bar
Suitable as limiter
Yes
Initial setting
1300 - 12000hPa
Bursting pressure
30bar
Number of auxiliary contacts as change-over contact
0
Engaging pressure
1.3 - 12bar
End setting
300 - 10300hPa
Thread size
Other
Max. operating pressure
12000hPa
Suitable as 2-point controller
Yes
Suitable as guard
No
Degree of protection (NEMA)
Other
Explosion-proof
No
Rated voltage Ue at AC 50 Hz
230 - 400V
Number of auxiliary contacts as normally closed contact
0
Electronic version
No
Number of normally closed contacts as main contact
3
Medium temperature
0 - 70°C
Type of electric connection
Screw connection
Pressure-switching differential
8.4bar
With display
No
Rated voltage Ue at AC 60 Hz
230 - 400V
Number of normally open contacts as main contact
0
With manual on/off switch
No
Number of auxiliary contacts as normally open contact
0
Initial value measuring range pressure
130000Pa
With hand operation
No
End value measuring range pressure
1200000Pa
Depth
98mm
Width
57mm
Height
106mm
Degree of protection (IP)
IP54
XMPA12C2242

Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Rated voltage Ue at DC
- .. -V
Adjustable current range
- .. -A
Max. operation pressure
12000hPa
Max. test pressure
-bar
Switching capacity at AC-3, 240 V
-kA
Type of pressure connection
G 3/8 inch
Switch off pressure
0.3 .. 10.3bar
Suitable as limiter
Initial setting
1300 .. 12000hPa
Bursting pressure
30bar
Number of auxiliary contacts as change-over contact
0
Engaging pressure
1.3 .. 12bar
End setting
300 .. 10300hPa
Thread size
Other
Max. operating pressure
12000hPa
Suitable as 2-point controller
Suitable as guard
Degree of protection (NEMA)
Other
Explosion-proof
Rated voltage Ue at AC 50 Hz
230 .. 400V
Number of auxiliary contacts as normally closed contact
0
Electronic version
Number of normally closed contacts as main contact
3
Medium temperature
0 .. 70°C
Type of electric connection
Screw connection
Pressure-switching differential
8.4bar
With display
Rated voltage Ue at AC 60 Hz
230 .. 400V
Number of normally open contacts as main contact
0
With manual on/off switch
Number of auxiliary contacts as normally open contact
0
Initial value measuring range pressure
130000Pa
With hand operation
End value measuring range pressure
1200000Pa
Depth
98mm
Width
57mm
Height
106mm
Degree of protection (IP)
IP54