Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP54
Number of auxiliary contacts as normally closed contact
3
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Type of electric connection
Other
Rated operation power at AC-3, 400 V
0kW
Rated operation current Ie at AC-3, 400 V
0A
Rated operation current Ie at AC-1, 400 V
0A
Number of normally open contacts as main contact
0
Number of normally closed contacts as main contact
0
Explosion-proof
No
Rated voltage Ue at AC 50 Hz
230 - 400V
Rated voltage Ue at AC 60 Hz
230 - 400V
Rated voltage Ue at DC
- - undefinedV
Adjustable current range
- - undefinedA
Max. operation pressure
25000hPa
With manual on/off switch
Yes
Electronic version
No
Bursting pressure
30bar
Suitable as 2-point controller
No
Suitable as guard
No
Medium temperature
70 - 70°C
Suitable as limiter
Yes
With hand operation
No
Pressure-switching differential
1bar
End setting
1300 - 12000hPa
Switch off pressure
- - undefinedbar
Engaging pressure
1 - 12bar
Initial setting
300 - 10300hPa
Max. test pressure
0bar
End value measuring range pressure
0Pa
Initial value measuring range pressure
0Pa
Switching capacity at AC-3, 240 V
0kA
From same serie
XMPE12C2542

Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP54
Number of auxiliary contacts as normally closed contact
3
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Type of electric connection
Other
Rated operation power at AC-3, 400 V
0kW
Rated operation current Ie at AC-3, 400 V
0A
Rated operation current Ie at AC-1, 400 V
0A
Number of normally open contacts as main contact
0
Number of normally closed contacts as main contact
0
Explosion-proof
Rated voltage Ue at AC 50 Hz
230 .. 400V
Rated voltage Ue at AC 60 Hz
230 .. 400V
Rated voltage Ue at DC
- .. undefinedV
Adjustable current range
- .. undefinedA
Max. operation pressure
25000hPa
With manual on/off switch
Electronic version
Bursting pressure
30bar
Suitable as 2-point controller
Suitable as guard
Medium temperature
70 .. 70°C
Suitable as limiter
With hand operation
Pressure-switching differential
1bar
End setting
1300 .. 12000hPa
Switch off pressure
- .. undefinedbar
Engaging pressure
1 .. 12bar
Initial setting
300 .. 10300hPa
Max. test pressure
0bar
End value measuring range pressure
0Pa
Initial value measuring range pressure
0Pa