Coating housingNickel-plated
Switching frequency1000Hz
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Suitable for safety functionsNo
Type of interface for safety communicationNone
Number of protected contact energized outputs0
Number of protected semiconductor outputs0
Type of electric connectionConnector M12
Type of switch functionNormally open contact
Rated control supply voltage Us at AC 50HZ- - -V
Construction type housingCylinder, screw-thread
Explosion safety category for gasNone
Rated control supply voltage Us at DC12 - 24V
Rated control supply voltage Us at AC 60HZ- - -V
Mechanical mounting condition for sensorConcise
With monitoring function downstream switching devicesNo
Category according to EN 954-11
Explosion safety category for dustNone
Performance level according to EN ISO 13849-1None
Interference resistance to magnetic fieldsImmune against magnetic DC- and AC-field
Max. output current at protected output200mA
Type of actuationMetallic Target
SIL according to IEC 61508None
Type of switching outputPNP/PNP