Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Category according to EN 954-1
1
Length of sensor
60mm
Number of protected semiconductor outputs
0
Type of switching output
PNP/PNP
Type of interface for safety communication
None
Type of interface
None
Mechanical mounting condition for sensor
Concise
Performance level according to EN ISO 13849-1
None
Max. output current at protected output
100mA
SIL according to IEC 61508
None
Cascadable
No
Number of contact energized outputs with signalling function
0
Switching distance
6mm
Diameter sensor
18mm
Coating housing
Nickel-plated
Suitable for safety functions
No
Type of actuation
Metallic Target
Type of electric connection
Connector M12
Number of protected contact energized outputs
0
Construction type housing
Cylinder, screw-thread
Number of semiconductor outputs with signalling function
1
Supply voltage
12 - 24V
Type of switch function
Breaker contact
Material housing
Metal
Compression-resistant
No
Explosion safety category for dust
None
Switching frequency
1000Hz
Interference resistance to magnetic fields
Immune against magnetic DC- and AC-field
Voltage type
AC/DC
With monitoring function downstream switching devices
No
Rated control supply voltage Us at DC
12 - 24V
Explosion safety category for gas
None
XS618B2PBL01M12

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Category according to EN 954-1
1
Length of sensor
60mm
Number of protected semiconductor outputs
0
Type of switching output
PNP/PNP
Type of interface for safety communication
None
Type of interface
None
Mechanical mounting condition for sensor
Concise
Performance level according to EN ISO 13849-1
None
Max. output current at protected output
100mA
SIL according to IEC 61508
None
Cascadable
Number of contact energized outputs with signalling function
0
Switching distance
6mm
Diameter sensor
18mm
Coating housing
Nickel-plated
Suitable for safety functions
Type of actuation
Metallic Target
Type of electric connection
Connector M12
Number of protected contact energized outputs
0
Construction type housing
Cylinder, screw-thread
Number of semiconductor outputs with signalling function
1
Supply voltage
12 .. 24V
Type of switch function
Breaker contact
Material housing
Metal
Compression-resistant
Explosion safety category for dust
None
Switching frequency
1000Hz
Interference resistance to magnetic fields
Immune against magnetic DC- and AC-field
Voltage type
AC/DC
With monitoring function downstream switching devices
Rated control supply voltage Us at DC
12 .. 24V
Explosion safety category for gas
None
We use cookies to enhance your experience.