Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
With time function
No
Pre failure notice
No
With reflector
Yes
Analogue output 0 mA ... 20 mA
No
With other analogue output
No
With communication interface AS-Interface
No
Setting procedure
Other
With communication interface analogue
No
Max. output current
100mA
With communication interface INTERBUS
No
Number of semiconductor outputs with signalling function
1
Type of electric connection
Connector M12
With communication interface DeviceNet
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Type of switch function
Programmable/configurable
With communication interface SSD
No
Diameter sensor
18mm
Material housing
Metal
With communication interface PROFIBUS
No
Analogue output 4 mA ... 20 mA
No
Number of protected contact energized outputs
0
Material of optical surface
Plastic
Sensing mode
Dark switching
Type of interface for safety communication
Other
Analogue output 0 V ... 10 V
No
Number of protected semiconductor outputs
1
Analogue output -10 V ... +10 V
No
Type of switching output
PNP/PNP
Rated switching distance
4000mm
With communication interface RS-485
No
With communication interface RS-422
No
With communication interface Ethernet
No
Construction type housing
Cylinder, screw-thread
Operation agent-safety class
Safety class 0
Max. switching distance
5500mm
Length of sensor
72mm
With communication interface CANOpen
No
Number of contact energized outputs with signalling function
0
With communication interface SSI
No
With communication interface RS-232
No
Type of light
Infrared light
Suitable for safety functions
No
Degree of protection (IP)
IP67K
With restart blockage
No
Laser protection class
None
Ambient temperature
-25 - 55°C
Switching frequency
500Hz
Voltage type
AC/DC
With monitoring function downstream switching devices
No
Type of safety according to IEC 61496-1
1
Rated control supply voltage Us at DC
12 - 24V
Response time
1ms
Max. output current at protected output
100mA
Min. reflector distance
1000mm
XU1N18PP341D

Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
With time function
Pre failure notice
With reflector
Analogue output 0 mA ... 20 mA
With other analogue output
With communication interface AS-Interface
Setting procedure
Other
With communication interface analogue
Max. output current
100mA
With communication interface INTERBUS
Number of semiconductor outputs with signalling function
1
Type of electric connection
Connector M12
With communication interface DeviceNet
Explosion safety category for gas
None
Explosion safety category for dust
None
Type of switch function
Programmable/configurable
With communication interface SSD
Diameter sensor
18mm
Material housing
Metal
With communication interface PROFIBUS
Analogue output 4 mA ... 20 mA
Number of protected contact energized outputs
0
Material of optical surface
Plastic
Sensing mode
Dark switching
Type of interface for safety communication
Other
Analogue output 0 V ... 10 V
Number of protected semiconductor outputs
1
Analogue output -10 V ... +10 V
Type of switching output
PNP/PNP
Rated switching distance
4000mm
With communication interface RS-485
With communication interface RS-422
With communication interface Ethernet
Construction type housing
Cylinder, screw-thread
Operation agent-safety class
Safety class 0
Max. switching distance
5500mm
Length of sensor
72mm
With communication interface CANOpen
Number of contact energized outputs with signalling function
0
With communication interface SSI
With communication interface RS-232
Type of light
Infrared light
Suitable for safety functions
Degree of protection (IP)
IP67K
With restart blockage
Laser protection class
None
Ambient temperature
-25 .. 55°C
Switching frequency
500Hz
Voltage type
AC/DC
With monitoring function downstream switching devices
Type of safety according to IEC 61496-1
1
Rated control supply voltage Us at DC
12 .. 24V
Response time
1ms
Max. output current at protected output
100mA
Min. reflector distance