Details

  • Sensors
  • Diffuse reflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of protected semiconductor outputs1
Ambient temperature-25 - 55°C
Number of semiconductor outputs with signalling function1
Voltage typeAC/DC
Switching frequency25Hz
With time functionNo
Material housingMetal
Number of contact energized outputs with signalling function0
Max. output current200mA
Suitable for safety functionsNo
Number of protected contact energized outputs0
Type of interface for safety communicationOther
Type of switching output2-wire
Rated control supply voltage Us at AC 60HZ24 - 240V
Type of electric connectionCable radial
Operation agent-safety classSafety class 0
Construction type housingCylinder, screw-thread
Rated control supply voltage Us at AC 50HZ24 - 240V
Type of lightInfrared light
Setting procedureOther
Laser protection classNone
Explosion safety category for gasNone
Rated control supply voltage Us at DC24 - 240V
Explosion safety category for dustNone
Light dot-mm²
With restart blockageNo
Type of safety according to IEC 61496-11
Switching voltage of OSSD at state "high"-V
Pre failure noticeNo
Min. reflector distance0.3mm
With monitoring function downstream switching devicesNo
Max. output current at protected output200mA
Type of switch functionNormally open contact (NO)
Transmission range of the safety field1m
Response time20ms
With communication interface INTERBUSNo
With communication interface analogueNo
Analogue output 0 mA ... 20 mANo
Analogue output 4 mA ... 20 mANo
With communication interface CANOpenNo
AWG-number-
With communication interface DeviceNetNo
Material of optical surfacePlastic
Width sensor-mm
With communication interface EthernetNo
Analogue output 0 V ... 10 VNo
Material of cable sheathPUR vulcanized
Wavelength of the sensor-nm
Height of sensor-mm
Degree of protection (IP)IP67K
With communication interface AS-InterfaceNo
Diameter sensor18mm
Analogue output -10 V ... +10 VNo
With communication interface SSDNo
With communication interface PROFIBUSNo
With communication interface SSINo
With communication interface RS-422No
With communication interface RS-232No
With communication interface RS-485No
Length of sensor97mm
With other analogue outputNo
With reflectorNo
Sensing modeDark switching
Operating distance400 - 400mm
Max. switching distance600mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XU5M18MA230W

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • Diffuse reflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of protected semiconductor outputs

1

Ambient temperature

-25 .. 55°C

Number of semiconductor outputs with signalling function

1

Voltage type

AC/DC

Switching frequency

25Hz

With time function

Material housing

Metal

Number of contact energized outputs with signalling function

0

Max. output current

200mA

Suitable for safety functions

Number of protected contact energized outputs

0

Type of interface for safety communication

Other

Type of switching output

2-wire

Rated control supply voltage Us at AC 60HZ

24 .. 240V

Type of electric connection

Cable radial

Operation agent-safety class

Safety class 0

Construction type housing

Cylinder, screw-thread

Rated control supply voltage Us at AC 50HZ

24 .. 240V

Type of light

Infrared light

Setting procedure

Other

Laser protection class

None

Explosion safety category for gas

None

Rated control supply voltage Us at DC

24 .. 240V

Explosion safety category for dust

None

Light dot

-mm²

With restart blockage

Type of safety according to IEC 61496-1

1

Switching voltage of OSSD at state "high"

-V

Pre failure notice

Min. reflector distance

0.3mm

With monitoring function downstream switching devices

Max. output current at protected output

200mA

Type of switch function

Normally open contact (NO)

Transmission range of the safety field

1m

Response time

20ms

With communication interface INTERBUS

With communication interface analogue

Analogue output 0 mA ... 20 mA

Analogue output 4 mA ... 20 mA

With communication interface CANOpen

AWG-number

-

With communication interface DeviceNet

Material of optical surface

Plastic

Width sensor

-mm

With communication interface Ethernet

Analogue output 0 V ... 10 V

Material of cable sheath

PUR vulcanized

Wavelength of the sensor

-nm

Height of sensor

-mm

Degree of protection (IP)

IP67K

With communication interface AS-Interface

Diameter sensor

18mm

Analogue output -10 V ... +10 V

With communication interface SSD

With communication interface PROFIBUS

With communication interface SSI

With communication interface RS-422

With communication interface RS-232

With communication interface RS-485

Length of sensor

97mm

With other analogue output

With reflector

Sensing mode

Dark switching

Operating distance

400 .. 400mm

Max. switching distance

600mm