Technical specifications
XU8M18MB230

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Sensors
- Light scanner with background masking
- 1 KOM
- SCHNEIDER
Technical specifications
Number of protected semiconductor outputs
1
Material housing
Metal
Suitable for safety functions
Ambient temperature
-25 .. 55°C
With time function
Adjustment range
120 .. 120mm
Number of contact energized outputs with signalling function
0
Number of semiconductor outputs with signalling function
1
Type of electric connection
Cable radial
Type of interface for safety communication
Other
Type of switching output
Other
Switching frequency
25Hz
Voltage type
AC/DC
Number of protected contact energized outputs
0
Type of switch function
Breaker contact (NC)
Explosion safety category for dust
None
Rated control supply voltage Us at DC
24 .. 240V
Explosion safety category for gas
None
Rated control supply voltage Us at AC 50HZ
24 .. 240V
Operation agent-safety class
Safety class 0
Max. output current
200mA
Setting procedure
Manual adjustment
Construction type housing
Cylinder, screw-thread
Laser protection class
None
Rated control supply voltage Us at AC 60HZ
24 .. 240V
Max. output current at protected output
200mA
Operating distance
120 .. 120mm
With monitoring function downstream switching devices
Min. reflector distance
-mm
Type of light
Infrared light
Response time
20ms
Type of safety according to IEC 61496-1
1
Transmission range of the safety field
-m
Switching voltage of OSSD at state "high"
-V
Material of optical surface
Plastic
Pre failure notice
Wavelength of the sensor
-nm
With restart blockage
Material of cable sheath
Other
Analogue output 0 V ... 10 V
Height of sensor
-mm
Analogue output 4 mA ... 20 mA
With communication interface analogue
Width sensor
-mm
Analogue output -10 V ... +10 V
Diameter sensor
18mm
AWG-number
-
Analogue output 0 mA ... 20 mA
Light dot
-mm²
Degree of protection (IP)
IP67K
With communication interface RS-485
With communication interface INTERBUS
With communication interface CANOpen
With communication interface SSD
With communication interface RS-422
With communication interface PROFIBUS
With communication interface SSI
With other analogue output
Max. switching distance
120mm
With communication interface DeviceNet
With reflector
Length of sensor
82mm
With communication interface AS-Interface
With communication interface Ethernet
Sensing mode
Dark switching
Rated switching distance
120mm
Operating distance
120 .. 120mm
With communication interface RS-232
Triangulation
Background fade-out