Aleta.hr
Main Product Image

XUB1APAWM12

Code: 1722441

ManufacturerSchneider
Catalog numberXUB1APAWM12
EAN code3389110148701

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage typeAC/DC
Max. output current100mA
Suitable for safety functionsNo
Switching frequency500Hz
With time functionNo
Ambient temperature-25 - 55°C
Material housingPlastic
Number of semiconductor outputs with signalling function1
Number of protected contact energized outputs0
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Type of switching outputPNP/PNP
Rated control supply voltage Us at DC12 - 24V
Type of electric connectionConnector M12
Rated control supply voltage Us at AC 60HZ- - -V
Type of interface for safety communicationOther
Rated control supply voltage Us at AC 50HZ- - -V
Type of switch functionNormally open contact (NO)
Setting procedureOther
Explosion safety category for dustNone
Explosion safety category for gasNone
Operation agent-safety classSafety class 0
Laser protection classNone
Construction type housingCylinder, screw-thread
Light dot-mm²
Type of lightInfrared light
Transmission range of the safety field-m
With restart blockageNo
Min. reflector distance1000mm
With monitoring function downstream switching devicesNo
Type of safety according to IEC 61496-11
Switching voltage of OSSD at state "high"-V
Response time1ms
Max. output current at protected output100mA
Pre failure noticeNo
Wavelength of the sensor-nm
Material of optical surfacePlastic
Analogue output -10 V ... +10 VNo
Analogue output 4 mA ... 20 mANo
Width sensor-mm
Degree of protection (IP)IP65
Analogue output 0 V ... 10 VNo
With communication interface CANOpenNo
Height of sensor-mm
With communication interface RS-422No
With communication interface AS-InterfaceNo
With reflectorYes
With communication interface PROFIBUSNo
With communication interface INTERBUSNo
Max. switching distance5500mm
Diameter sensor18mm
With communication interface SSINo
With communication interface analogueNo
With communication interface RS-232No
With communication interface SSDNo
With communication interface DeviceNetNo
With other analogue outputNo
With communication interface EthernetNo
With communication interface RS-485No
Length of sensor76mm
Analogue output 0 mA ... 20 mANo
Rated switching distance4000mm
Sensing modeDark switching
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XUB1APAWM12

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage type

AC/DC

Max. output current

100mA

Suitable for safety functions

Switching frequency

500Hz

With time function

Ambient temperature

-25 .. 55°C

Material housing

Plastic

Number of semiconductor outputs with signalling function

1

Number of protected contact energized outputs

0

Number of contact energized outputs with signalling function

0

Number of protected semiconductor outputs

1

Type of switching output

PNP/PNP

Rated control supply voltage Us at DC

12 .. 24V

Type of electric connection

Connector M12

Rated control supply voltage Us at AC 60HZ

- .. -V

Type of interface for safety communication

Other

Rated control supply voltage Us at AC 50HZ

- .. -V

Type of switch function

Normally open contact (NO)

Setting procedure

Other

Explosion safety category for dust

None

Explosion safety category for gas

None

Operation agent-safety class

Safety class 0

Laser protection class

None

Construction type housing

Cylinder, screw-thread

Light dot

-mm²

Type of light

Infrared light

Transmission range of the safety field

-m

With restart blockage

Min. reflector distance

1000mm

With monitoring function downstream switching devices

Type of safety according to IEC 61496-1

1

Switching voltage of OSSD at state "high"

-V

Response time

1ms

Max. output current at protected output

100mA

Pre failure notice

Wavelength of the sensor

-nm

Material of optical surface

Plastic

Analogue output -10 V ... +10 V

Analogue output 4 mA ... 20 mA

Width sensor

-mm

Degree of protection (IP)

IP65

Analogue output 0 V ... 10 V

With communication interface CANOpen

Height of sensor

-mm

With communication interface RS-422

With communication interface AS-Interface

With reflector

With communication interface PROFIBUS

With communication interface INTERBUS

Max. switching distance

5500mm

Diameter sensor

18mm

With communication interface SSI

With communication interface analogue

With communication interface RS-232

With communication interface SSD

With communication interface DeviceNet

With other analogue output

With communication interface Ethernet

With communication interface RS-485

Length of sensor

76mm

Analogue output 0 mA ... 20 mA

Rated switching distance

4000mm

Sensing mode

Dark switching

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.