Aleta.hr
Main Product Image

XUB1BPANL5

Code: 1722458

ManufacturerSchneider
Catalog numberXUB1BPANL5
EAN code3389110396003

















Details

  • Sensors
  • Reflection light barrier
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP67
Voltage typeDC
Material housingMetal
Rated control supply voltage Us at DC12 - 24V
Rated control supply voltage Us at AC 50HZ- - undefinedV
Rated control supply voltage Us at AC 60HZ- - undefinedV
Type of electric connectionCable
Explosion safety category for dustNone
Length of sensor46mm
Width sensor0mm
Diameter sensor18mm
Type of interface for safety communicationOther
Construction type housingCylinder, screw-thread
With monitoring function downstream switching devicesNo
Number of protected semiconductor outputs1
Type of switching outputPNP
Type of switch functionNormally open contact (NO)
Switching frequency500Hz
Number of semiconductor outputs with signalling function1
Explosion safety category for gasNone
Height of sensor0mm
Suitable for safety functionsNo
Number of protected contact energized outputs0
Number of contact energized outputs with signalling function0
Max. output current at protected output100mA
Ambient temperature-25 - 55°C
Max. output current100mA
With restart blockageNo
Response time1ms
With communication interface RS-232No
Transmission range of the safety field0m
Type of safety according to IEC 61496-11
Wavelength of the sensor0nm
Switching voltage of OSSD at state "high"0V
Operation agent-safety classSafety class 0
With communication interface EthernetNo
With communication interface RS-485No
Setting procedureOther
Analogue output 0 V ... 10 VNo
With time functionNo
Analogue output 0 mA ... 20 mANo
Analogue output -10 V ... +10 VNo
Analogue output 4 mA ... 20 mANo
Type of lightInfrared light
Laser protection classNone
With other analogue outputNo
Material of optical surfacePlastic
With communication interface CANOpenNo
Pre failure noticeNo
With communication interface AS-InterfaceNo
With communication interface INTERBUSNo
With communication interface analogueNo
With communication interface DeviceNetNo
With communication interface SSDNo
With communication interface RS-422No
With communication interface PROFIBUSNo
With communication interface SSINo
Max. switching distance5500mm
With reflectorNo
Sensing modeLight-/dark switching
Min. reflector distance1000mm
Light dot0mm²
Rated switching distance4000mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XUB1BPANL5

Main Product Image

Details

  • Sensors
  • Reflection light barrier
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP67

Voltage type

DC

Material housing

Metal

Rated control supply voltage Us at DC

12 .. 24V

Rated control supply voltage Us at AC 50HZ

- .. undefinedV

Rated control supply voltage Us at AC 60HZ

- .. undefinedV

Type of electric connection

Cable

Explosion safety category for dust

None

Length of sensor

46mm

Width sensor

0mm

Diameter sensor

18mm

Type of interface for safety communication

Other

Construction type housing

Cylinder, screw-thread

With monitoring function downstream switching devices

Number of protected semiconductor outputs

1

Type of switching output

PNP

Type of switch function

Normally open contact (NO)

Switching frequency

500Hz

Number of semiconductor outputs with signalling function

1

Explosion safety category for gas

None

Height of sensor

0mm

Suitable for safety functions

Number of protected contact energized outputs

0

Number of contact energized outputs with signalling function

0

Max. output current at protected output

100mA

Ambient temperature

-25 .. 55°C

Max. output current

100mA

With restart blockage

Response time

1ms

With communication interface RS-232

Transmission range of the safety field

0m

Type of safety according to IEC 61496-1

1

Wavelength of the sensor

0nm

Switching voltage of OSSD at state "high"

0V

Operation agent-safety class

Safety class 0

With communication interface Ethernet

With communication interface RS-485

Setting procedure

Other

Analogue output 0 V ... 10 V

With time function

Analogue output 0 mA ... 20 mA

Analogue output -10 V ... +10 V

Analogue output 4 mA ... 20 mA

Type of light

Infrared light

Laser protection class

None

With other analogue output

Material of optical surface

Plastic

With communication interface CANOpen

Pre failure notice

With communication interface AS-Interface

With communication interface INTERBUS

With communication interface analogue

With communication interface DeviceNet

With communication interface SSD

With communication interface RS-422

With communication interface PROFIBUS

With communication interface SSI

Max. switching distance

5500mm

With reflector

Sensing mode

Light-/dark switching

Min. reflector distance

1000mm

Light dot

0mm²

Rated switching distance

4000mm

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.