Aleta.hr
Main Product Image

XUB2APAWM12R

Code: 1722485

ManufacturerSchneider
Catalog numberXUB2APAWM12R
EAN code3389110149555

Details

  • Sensors
  • Through beam photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Type of interface for safety communicationOther
Number of protected semiconductor outputs1
Max. opening angle0°
Ambient temperature-25 - 55°C
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Switching frequency500Hz
Suitable for safety functionsNo
Type of electric connectionConnector M12
With time functionNo
Material housingPlastic
Max. output current100mA
Number of protected contact energized outputs0
Voltage typeAC/DC
Material of optical surfacePlastic
Type of switching outputPNP/PNP
Rated control supply voltage Us at AC 60HZ- - -V
Operation agent-safety classSafety class 0
Response time1ms
Laser protection classNone
Pre failure noticeNo
Setting procedureOther
Scope of delivery of the one-way systemReceiver
Light dot-mm²
Construction type housingCylinder, screw-thread
Type of lightInfrared light
Type of safety according to IEC 61496-11
Type of switch functionNormally open contact (NO)
Switching voltage of OSSD at state "high"-V
Explosion safety category for dustNone
Max. output current at protected output100mA
Rated control supply voltage Us at DC12 - 24V
Rated control supply voltage Us at AC 50HZ- - -V
With monitoring function downstream switching devicesNo
Wavelength of the sensor-nm
With restart blockageNo
Explosion safety category for gasNone
Transmission range of the safety field-m
Min. reflector distance5000mm
AWG-number-
With communication interface PROFIBUSNo
Analogue output 0 V ... 10 VNo
With communication interface INTERBUSNo
Analogue output 0 mA ... 20 mANo
With communication interface analogueNo
Max. switching distance20000mm
With communication interface RS-232No
Height of sensor-mm
With communication interface RS-485No
Analogue output 4 mA ... 20 mANo
With communication interface RS-422No
With communication interface AS-InterfaceNo
Degree of protection (IP)IP65
With communication interface SSDNo
Width sensor-mm
Material of cable sheathOther
With communication interface DeviceNetNo
With communication interface CANOpenNo
Analogue output -10 V ... +10 VNo
Length of sensor76mm
With communication interface EthernetNo
With communication interface SSINo
With reflectorNo
Diameter sensor18mm
With other analogue outputNo
Rated switching distance15000mm
Sensing modeDark switching
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XUB2APAWM12R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • Through beam photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Type of interface for safety communication

Other

Number of protected semiconductor outputs

1

Max. opening angle

0°

Ambient temperature

-25 .. 55°C

Number of semiconductor outputs with signalling function

1

Number of contact energized outputs with signalling function

0

Switching frequency

500Hz

Suitable for safety functions

Type of electric connection

Connector M12

With time function

Material housing

Plastic

Max. output current

100mA

Number of protected contact energized outputs

0

Voltage type

AC/DC

Material of optical surface

Plastic

Type of switching output

PNP/PNP

Rated control supply voltage Us at AC 60HZ

- .. -V

Operation agent-safety class

Safety class 0

Response time

1ms

Laser protection class

None

Pre failure notice

Setting procedure

Other

Scope of delivery of the one-way system

Receiver

Light dot

-mm²

Construction type housing

Cylinder, screw-thread

Type of light

Infrared light

Type of safety according to IEC 61496-1

1

Type of switch function

Normally open contact (NO)

Switching voltage of OSSD at state "high"

-V

Explosion safety category for dust

None

Max. output current at protected output

100mA

Rated control supply voltage Us at DC

12 .. 24V

Rated control supply voltage Us at AC 50HZ

- .. -V

With monitoring function downstream switching devices

Wavelength of the sensor

-nm

With restart blockage

Explosion safety category for gas

None

Transmission range of the safety field

-m

Min. reflector distance

5000mm

AWG-number

-

With communication interface PROFIBUS

Analogue output 0 V ... 10 V

With communication interface INTERBUS

Analogue output 0 mA ... 20 mA

With communication interface analogue

Max. switching distance

20000mm

With communication interface RS-232

Height of sensor

-mm

With communication interface RS-485

Analogue output 4 mA ... 20 mA

With communication interface RS-422

With communication interface AS-Interface

Degree of protection (IP)

IP65

With communication interface SSD

Width sensor

-mm

Material of cable sheath

Other

With communication interface DeviceNet

With communication interface CANOpen

Analogue output -10 V ... +10 V

Length of sensor

76mm

With communication interface Ethernet

With communication interface SSI

With reflector

Diameter sensor

18mm

With other analogue output

Rated switching distance

15000mm

Sensing mode

Dark switching

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.