  • Sensors
  • Light scanner, energetic
  • 1 KOM
  • SCHNEIDER

Technical specifications

With time functionNo
Max. output current100mA
Voltage typeDC
Material housingMetal
Ambient temperature-25 - 55°C
Suitable for safety functionsNo
Number of semiconductor outputs with signalling function1
Switching frequency500Hz
Number of contact energized outputs with signalling function0
Type of switching outputNPN
Setting procedureOther
Number of protected contact energized outputs0
Type of interface for safety communicationOther
Rated control supply voltage Us at DC12 - 24V
Type of electric connectionCable
Explosion safety category for dustNone
Operation agent-safety classSafety class 0
Type of switch functionBreaker contact (NC)
Type of lightInfrared light
With restart blockageNo
Explosion safety category for gasNone
Max. output current at protected output100mA
Rated control supply voltage Us at AC 60HZ- - undefinedV
Min. reflector distance0mm
Laser protection classNone
Light dot0mm²
With monitoring function downstream switching devicesNo
Number of protected semiconductor outputs1
Rated control supply voltage Us at AC 50HZ- - undefinedV
Construction type housingCylinder, screw-thread
Response time1ms
Type of safety according to IEC 61496-11
Switching voltage of OSSD at state "high"0V
Transmission range of the safety field3m
Material of cable sheathPUR vulcanized
Degree of protection (IP)IP67
Analogue output 0 mA ... 20 mANo
Analogue output 0 V ... 10 VNo
Analogue output 4 mA ... 20 mANo
With communication interface EthernetNo
Analogue output -10 V ... +10 VNo
Height of sensor0mm
Width sensor0mm
With communication interface AS-InterfaceNo
Pre failure noticeNo
With communication interface analogueNo
With communication interface CANOpenNo
With communication interface DeviceNetNo
AWG-number0
Wavelength of the sensor0nm
Diameter sensor18mm
With communication interface INTERBUSNo
Material of optical surfacePlastic
With communication interface RS-232No
With communication interface PROFIBUSNo
With communication interface RS-422No
With communication interface SSINo
With communication interface RS-485No
With communication interface SSDNo
With other analogue outputNo
Max. switching distance150mm
Operating distance100 - 100mm
Sensing modeLight switching
Length of sensor46mm
With reflectorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XUB4BNBNL2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • Light scanner, energetic
  • 1 KOM
  • SCHNEIDER

Technical specifications

With time function

Max. output current

100mA

Voltage type

DC

Material housing

Metal

Ambient temperature

-25 .. 55°C

Suitable for safety functions

Number of semiconductor outputs with signalling function

1

Switching frequency

500Hz

Number of contact energized outputs with signalling function

0

Type of switching output

NPN

Setting procedure

Other

Number of protected contact energized outputs

0

Type of interface for safety communication

Other

Rated control supply voltage Us at DC

12 .. 24V

Type of electric connection

Cable

Explosion safety category for dust

None

Operation agent-safety class

Safety class 0

Type of switch function

Breaker contact (NC)

Type of light

Infrared light

With restart blockage

Explosion safety category for gas

None

Max. output current at protected output

100mA

Rated control supply voltage Us at AC 60HZ

- .. undefinedV

Min. reflector distance

0mm

Laser protection class

None

Light dot

0mm²

With monitoring function downstream switching devices

Number of protected semiconductor outputs

1

Rated control supply voltage Us at AC 50HZ

- .. undefinedV

Construction type housing

Cylinder, screw-thread

Response time

1ms

Type of safety according to IEC 61496-1

1

Switching voltage of OSSD at state "high"

0V

Transmission range of the safety field

3m

Material of cable sheath

PUR vulcanized

Degree of protection (IP)

IP67

Analogue output 0 mA ... 20 mA

Analogue output 0 V ... 10 V

Analogue output 4 mA ... 20 mA

With communication interface Ethernet

Analogue output -10 V ... +10 V

Height of sensor

0mm

Width sensor

0mm

With communication interface AS-Interface

Pre failure notice

With communication interface analogue

With communication interface CANOpen

With communication interface DeviceNet

AWG-number

0

Wavelength of the sensor

0nm

Diameter sensor

18mm

With communication interface INTERBUS

Material of optical surface

Plastic

With communication interface RS-232

With communication interface PROFIBUS

With communication interface RS-422

With communication interface SSI

With communication interface RS-485

With communication interface SSD

With other analogue output

Max. switching distance

150mm

Operating distance

100 .. 100mm

Sensing mode

Light switching

Length of sensor

46mm