Details
- Sensors
- Diffuse reflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
-mm
Switching voltage of OSSD at state "high"
-V
Wavelength of the sensor
-nm
Light dot
-mm²
AWG-number
-
Operating distance
1000 - 1000mm
Operating distance
1000 - 1000mm
With time function
No
Pre failure notice
No
With reflector
No
Analogue output 4 mA ... 20 mA
No
Analogue output 0 V ... 10 V
No
Analogue output -10 V ... +10 V
No
With other analogue output
No
Max. switching distance
1000mm
Max. output current
1500mA
Setting procedure
Other
Analogue output 0 mA ... 20 mA
No
Type of light
Infrared light
Material of cable sheath
Polyvinyl chloride (PVC)
Laser protection class
Other
With restart blockage
No
Suitable for safety functions
No
Degree of protection (IP)
IP65
Ambient temperature
-25 - 55°C
Rated control supply voltage Us at AC 50HZ
24 - 240V
Rated control supply voltage Us at AC 60HZ
24 - 240V
Rated control supply voltage Us at DC
24 - 240V
With communication interface SSI
No
With communication interface SSD
No
Number of protected contact energized outputs
0
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 0
With communication interface analogue
No
Number of semiconductor outputs with signalling function
0
Number of protected semiconductor outputs
0
Type of switching output
Relay contact
Type of electric connection
Cable radial
Number of contact energized outputs with signalling function
1
Explosion safety category for gas
None
Width sensor
18mm
Construction type housing
Cuboid
Min. reflector distance
0.3mm
Material of optical surface
Plastic
Response time
25ms
Type of switch function
Change-over contact (NO/NC)
With communication interface RS-232
No
With communication interface RS-485
No
With communication interface DeviceNet
No
With communication interface AS-Interface
No
Material housing
Plastic
Length of sensor
50mm
Max. output current at protected output
100mA
Height of sensor
50mm
With communication interface INTERBUS
No
With communication interface RS-422
No
With communication interface PROFIBUS
No
With communication interface Ethernet
No
With communication interface CANOpen
No
Type of safety according to IEC 61496-1
1
Switching frequency
20Hz
With monitoring function downstream switching devices
No
Transmission range of the safety field
0.3m
Sensing mode
Dark switching
Voltage type
AC/DC
Explosion safety category for dust
None
From same serie
XUK5ARCNL2

Details
- Sensors
- Diffuse reflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
-mm
Switching voltage of OSSD at state "high"
-V
Wavelength of the sensor
-nm
Light dot
-mm²
AWG-number
-
Operating distance
1000 .. 1000mm
Operating distance
1000 .. 1000mm
With time function
Pre failure notice
With reflector
Analogue output 4 mA ... 20 mA
Analogue output 0 V ... 10 V
Analogue output -10 V ... +10 V
With other analogue output
Max. switching distance
1000mm
Max. output current
1500mA
Setting procedure
Other
Analogue output 0 mA ... 20 mA
Type of light
Infrared light
Material of cable sheath
Polyvinyl chloride (PVC)
Laser protection class
Other
With restart blockage
Suitable for safety functions
Degree of protection (IP)
IP65
Ambient temperature
-25 .. 55°C
Rated control supply voltage Us at AC 50HZ
24 .. 240V
Rated control supply voltage Us at AC 60HZ
24 .. 240V
Rated control supply voltage Us at DC
24 .. 240V
With communication interface SSI
With communication interface SSD
Number of protected contact energized outputs
0
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 0
With communication interface analogue
Number of semiconductor outputs with signalling function
0
Number of protected semiconductor outputs
0
Type of switching output
Relay contact
Type of electric connection
Cable radial
Number of contact energized outputs with signalling function
1
Explosion safety category for gas
None
Width sensor
18mm
Construction type housing
Cuboid
Min. reflector distance
0.3mm
Material of optical surface
Plastic
Response time
25ms
Type of switch function
Change-over contact (NO/NC)
With communication interface RS-232
With communication interface RS-485
With communication interface DeviceNet
With communication interface AS-Interface
Material housing
Plastic
Length of sensor
50mm
Max. output current at protected output
100mA
Height of sensor
50mm
With communication interface INTERBUS
With communication interface RS-422
With communication interface PROFIBUS
With communication interface Ethernet
With communication interface CANOpen
Type of safety according to IEC 61496-1
1
Switching frequency
20Hz
With monitoring function downstream switching devices
Transmission range of the safety field
0.3m
Sensing mode
Dark switching
Voltage type
AC/DC
Explosion safety category for dust
None
From same serie