Aleta.hr
Main Product Image

XUM0AKSAM8T

Code: 1722902

ManufacturerSchneider
Catalog numberXUM0AKSAM8T
EAN code3389110164626

















Details

  • Sensors
  • Through beam photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Pre failure noticeNo
Max. switching distance14000mm
Max. opening angle0°
Scope of delivery of the one-way systemTransmitter
Rated switching distance10000mm
With time functionNo
Max. output current0mA
With reflectorNo
Analogue output 0 V ... 10 VNo
With other analogue outputNo
Analogue output 4 mA ... 20 mANo
Analogue output 0 mA ... 20 mANo
With communication interface AS-InterfaceNo
With communication interface analogueNo
Setting procedureTeach-In
With communication interface DeviceNetNo
With communication interface PROFIBUSNo
Analogue output -10 V ... +10 VNo
Switching frequency250Hz
Type of safety according to IEC 61496-11
Switching voltage of OSSD at state "high"0V
Voltage typeDC
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ0 - 0V
Laser protection classNone
Rated control supply voltage Us at DC12 - 24V
Type of lightInfrared light
With monitoring function downstream switching devicesNo
Wavelength of the sensor0nm
Light dot0mm²
AWG-number0
Number of protected contact energized outputs0
Type of switching outputOther
Type of interface for safety communicationOther
Width sensor12mm
Height of sensor45mm
Length of sensor20mm
Material of optical surfacePlastic
Sensing modeDark switching
Operation agent-safety classSafety class 0
Diameter sensor0mm
Type of electric connectionConnector M8
With communication interface CANOpenNo
With communication interface EthernetNo
Number of semiconductor outputs with signalling function0
Number of contact energized outputs with signalling function0
With communication interface RS-232No
Construction type housingSpecial construction
With communication interface RS-485No
Number of protected semiconductor outputs0
With communication interface INTERBUSNo
Type of switch functionOther
With communication interface SSINo
Material housingPlastic
With communication interface RS-422No
Explosion safety category for dustNone
With communication interface SSDNo
Material of cable sheathOther
With restart blockageNo
Suitable for safety functionsNo
Degree of protection (IP)IP65
Explosion safety category for gasNone
Ambient temperature-25 - 55°C
Max. output current at protected output100mA
Min. reflector distance5000mm
Response time2ms
Transmission range of the safety field0m
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XUM0AKSAM8T

Main Product Image

Details

  • Sensors
  • Through beam photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Pre failure notice

Max. switching distance

14000mm

Max. opening angle

0°

Scope of delivery of the one-way system

Transmitter

Rated switching distance

10000mm

With time function

Max. output current

0mA

With reflector

Analogue output 0 V ... 10 V

With other analogue output

Analogue output 4 mA ... 20 mA

Analogue output 0 mA ... 20 mA

With communication interface AS-Interface

With communication interface analogue

Setting procedure

Teach-In

With communication interface DeviceNet

With communication interface PROFIBUS

Analogue output -10 V ... +10 V

Switching frequency

250Hz

Type of safety according to IEC 61496-1

1

Switching voltage of OSSD at state "high"

0V

Voltage type

DC

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Laser protection class

None

Rated control supply voltage Us at DC

12 .. 24V

Type of light

Infrared light

With monitoring function downstream switching devices

Wavelength of the sensor

0nm

Light dot

0mm²

AWG-number

0

Number of protected contact energized outputs

0

Type of switching output

Other

Type of interface for safety communication

Other

Width sensor

12mm

Height of sensor

45mm

Length of sensor

20mm

Material of optical surface

Plastic

Sensing mode

Dark switching

Operation agent-safety class

Safety class 0

Diameter sensor

0mm

Type of electric connection

Connector M8

With communication interface CANOpen

With communication interface Ethernet

Number of semiconductor outputs with signalling function

0

Number of contact energized outputs with signalling function

0

With communication interface RS-232

Construction type housing

Special construction

With communication interface RS-485

Number of protected semiconductor outputs

0

With communication interface INTERBUS

Type of switch function

Other

With communication interface SSI

Material housing

Plastic

With communication interface RS-422

Explosion safety category for dust

None

With communication interface SSD

Material of cable sheath

Other

With restart blockage

Suitable for safety functions

Degree of protection (IP)

IP65

Explosion safety category for gas

None

Ambient temperature

-25 .. 55°C

Max. output current at protected output

100mA

Min. reflector distance

5000mm

Response time

2ms

Transmission range of the safety field

0m

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.