Catalog numberXUM2ANCNL2R
EAN code3389119034838

Details

  • Sensors
  • One-way light barrier
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage typeDC
Max. output current100mA
With time functionNo
Number of semiconductor outputs with signalling function1
Max. opening angle-°
Switching frequency1000Hz
Ambient temperature-30 - 60°C
Material housingPlastic
Suitable for safety functionsNo
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
Operation agent-safety classSafety class 0
Rated control supply voltage Us at DC12 - 24V
Rated control supply voltage Us at AC 60HZ- - -V
Rated control supply voltage Us at AC 50HZ- - -V
Type of electric connectionCable
Scope of delivery of the one-way systemReceiver
Explosion safety category for gasNone
Type of interface for safety communicationOther
Type of switch functionChange-over contact (NO/NC)
Construction type housingSpecial construction
Type of switching outputNPN
Explosion safety category for dustNone
Min. reflector distance-mm
Max. output current at protected output100mA
Setting procedureManual adjustment
Light dot-mm²
Laser protection classNone
Type of lightPolarity free red light
Switching voltage of OSSD at state "high"-V
With restart blockageNo
Transmission range of the safety field-m
Type of safety according to IEC 61496-11
Response time0.5ms
With monitoring function downstream switching devicesNo
Pre failure noticeNo
Wavelength of the sensor-nm
Analogue output 0 V ... 10 VNo
Degree of protection (IP)IP65
Material of cable sheathPolyvinyl chloride (PVC)
Material of optical surfacePlastic
Analogue output -10 V ... +10 VNo
Analogue output 4 mA ... 20 mANo
Width sensor11mm
With communication interface AS-InterfaceNo
With communication interface DeviceNetNo
With communication interface CANOpenNo
Height of sensor34mm
AWG-number-
Diameter sensor-mm
Analogue output 0 mA ... 20 mANo
With communication interface analogueNo
With communication interface SSDNo
With communication interface RS-485No
With communication interface SSINo
With communication interface EthernetNo
With communication interface PROFIBUSNo
With communication interface RS-422No
With communication interface INTERBUSNo
With communication interface RS-232No
Length of sensor-mm
Max. switching distance-mm
With reflectorNo
Sensing modeLight-/dark switching
With other analogue outputNo
Rated switching distance15000mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XUM2ANCNL2R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • One-way light barrier
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage type

DC

Max. output current

100mA

With time function

Number of semiconductor outputs with signalling function

1

Max. opening angle

-°

Switching frequency

1000Hz

Ambient temperature

-30 .. 60°C

Material housing

Plastic

Suitable for safety functions

Number of contact energized outputs with signalling function

0

Number of protected semiconductor outputs

1

Number of protected contact energized outputs

0

Operation agent-safety class

Safety class 0

Rated control supply voltage Us at DC

12 .. 24V

Rated control supply voltage Us at AC 60HZ

- .. -V

Rated control supply voltage Us at AC 50HZ

- .. -V

Type of electric connection

Cable

Scope of delivery of the one-way system

Receiver

Explosion safety category for gas

None

Type of interface for safety communication

Other

Type of switch function

Change-over contact (NO/NC)

Construction type housing

Special construction

Type of switching output

NPN

Explosion safety category for dust

None

Min. reflector distance

-mm

Max. output current at protected output

100mA

Setting procedure

Manual adjustment

Light dot

-mm²

Laser protection class

None

Type of light

Polarity free red light

Switching voltage of OSSD at state "high"

-V

With restart blockage

Transmission range of the safety field

-m

Type of safety according to IEC 61496-1

1

Response time

0.5ms

With monitoring function downstream switching devices

Pre failure notice

Wavelength of the sensor

-nm

Analogue output 0 V ... 10 V

Degree of protection (IP)

IP65

Material of cable sheath

Polyvinyl chloride (PVC)

Material of optical surface

Plastic

Analogue output -10 V ... +10 V

Analogue output 4 mA ... 20 mA

Width sensor

11mm

With communication interface AS-Interface

With communication interface DeviceNet

With communication interface CANOpen

Height of sensor

34mm

AWG-number

-

Diameter sensor

-mm

Analogue output 0 mA ... 20 mA

With communication interface analogue

With communication interface SSD

With communication interface RS-485

With communication interface SSI

With communication interface Ethernet

With communication interface PROFIBUS

With communication interface RS-422

With communication interface INTERBUS

With communication interface RS-232

Length of sensor

-mm

Max. switching distance

-mm

With reflector

Sensing mode

Light-/dark switching

With other analogue output

Rated switching distance

15000mm

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.