Aleta.hr
Main Product Image

Item is no longer available for sale!

XUVF30M8

Code: 1723244

ManufacturerSchneider
Catalog numberXUVF30M8
Type
EAN code3389110168891

Details

  • Sensors
  • Optical frame sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. output current100mA
Material housingMetal
Voltage typeAC/DC
Type of switch functionProgrammable/configurable
Rated control supply voltage Us at DC24 - 24V
Type of switching outputPNP/NPN
Switching frequency500Hz
Number of contact energized outputs with signalling function0
Ambient temperature0 - 60°C
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
With time functionYes
Rated control supply voltage Us at AC 50HZ- - -V
Type of interface for safety communicationOther
Type of electric connectionConnector M8
Rated control supply voltage Us at AC 60HZ- - -V
Suitable for safety functionsNo
Number of semiconductor outputs with signalling function1
Operation agent-safety classSafety class 0
Type of lightInfrared light
Explosion safety category for dustNone
Min. reflector distance-mm
Light dot-mm²
Laser protection classNone
Explosion safety category for gasNone
Construction type housingSpecial construction
Max. output current at protected output100mA
Setting procedureManual adjustment
Wavelength of the sensor-nm
Pre failure noticeNo
Type of safety according to IEC 61496-11
Material of cable sheathOther
With restart blockageNo
Analogue output 4 mA ... 20 mANo
Response time1ms
Analogue output -10 V ... +10 VNo
Material of optical surfacePlastic
Degree of protection (IP)IP65
Transmission range of the safety field-m
With monitoring function downstream switching devicesNo
Analogue output 0 V ... 10 VNo
Analogue output 0 mA ... 20 mANo
Switching voltage of OSSD at state "high"-V
AWG-number-
With communication interface analogueNo
With communication interface DeviceNetNo
Diameter sensor-mm
With communication interface EthernetNo
Height of sensor50mm
With communication interface CANOpenNo
Width sensor108mm
With communication interface INTERBUSNo
With communication interface AS-InterfaceNo
With reflectorNo
With communication interface PROFIBUSNo
Frame opening cross30mm
Max. switching distance-mm
With other analogue outputNo
With communication interface SSINo
Sensing modeDark switching
With communication interface RS-232No
With communication interface SSDNo
Frame opening lengthwise30mm
Length of sensor15mm
Rated switching distance-mm
With communication interface RS-485No
With communication interface RS-422No
Min. object size2mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

XUVF30M8

Main Product Image

Details

  • Sensors
  • Optical frame sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. output current

100mA

Material housing

Metal

Voltage type

AC/DC

Type of switch function

Programmable/configurable

Rated control supply voltage Us at DC

24 .. 24V

Type of switching output

PNP/NPN

Switching frequency

500Hz

Number of contact energized outputs with signalling function

0

Ambient temperature

0 .. 60°C

Number of protected semiconductor outputs

1

Number of protected contact energized outputs

0

With time function

Rated control supply voltage Us at AC 50HZ

- .. -V

Type of interface for safety communication

Other

Type of electric connection

Connector M8

Rated control supply voltage Us at AC 60HZ

- .. -V

Suitable for safety functions

Number of semiconductor outputs with signalling function

1

Operation agent-safety class

Safety class 0

Type of light

Infrared light

Explosion safety category for dust

None

Min. reflector distance

-mm

Light dot

-mm²

Laser protection class

None

Explosion safety category for gas

None

Construction type housing

Special construction

Max. output current at protected output

100mA

Setting procedure

Manual adjustment

Wavelength of the sensor

-nm

Pre failure notice

Type of safety according to IEC 61496-1

1

Material of cable sheath

Other

With restart blockage

Analogue output 4 mA ... 20 mA

Response time

1ms

Analogue output -10 V ... +10 V

Material of optical surface

Plastic

Degree of protection (IP)

IP65

Transmission range of the safety field

-m

With monitoring function downstream switching devices

Analogue output 0 V ... 10 V

Analogue output 0 mA ... 20 mA

Switching voltage of OSSD at state "high"

-V

AWG-number

-

With communication interface analogue

With communication interface DeviceNet

Diameter sensor

-mm

With communication interface Ethernet

Height of sensor

50mm

With communication interface CANOpen

Width sensor

108mm

With communication interface INTERBUS

With communication interface AS-Interface

With reflector

With communication interface PROFIBUS

Frame opening cross

30mm

Max. switching distance

-mm

With other analogue output

With communication interface SSI

Sensing mode

Dark switching

With communication interface RS-232

With communication interface SSD

Frame opening lengthwise

30mm

Length of sensor

15mm

Rated switching distance

-mm

With communication interface RS-485

With communication interface RS-422

Min. object size

2mm

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.