Aleta.hr
Main Product Image

XUX0AKSAM12T

Code: 1723254

ManufacturerSchneider
Catalog numberXUX0AKSAM12T
EAN code3389110168037

Details

  • Sensors
  • Through beam photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage typeDC
Material housingPlastic
Ambient temperature-25 - 55°C
Type of interface for safety communicationOther
Type of switch functionOther
Max. output current100mA
Number of protected contact energized outputs0
Switching frequency250Hz
Suitable for safety functionsNo
Type of switching outputOther
Type of electric connectionConnector M12
Number of protected semiconductor outputs0
With time functionNo
Number of contact energized outputs with signalling function0
Max. opening angle0°
Rated control supply voltage Us at AC 50HZ- - -V
Number of semiconductor outputs with signalling function0
Explosion safety category for dustNone
Operation agent-safety classSafety class 0
Rated control supply voltage Us at DC12 - 24V
Setting procedureOther
Explosion safety category for gasNone
Rated control supply voltage Us at AC 60HZ- - -V
Construction type housingCuboid
Scope of delivery of the one-way systemTransmitter and receiver
Laser protection classNone
Type of lightInfrared light
Light dot-mm²
Type of safety according to IEC 61496-11
Min. reflector distance30000mm
Response time2ms
Max. output current at protected output100mA
Transmission range of the safety field-m
Switching voltage of OSSD at state "high"-V
With monitoring function downstream switching devicesNo
With restart blockageNo
Wavelength of the sensor-nm
Pre failure noticeNo
Material of cable sheathOther
Diameter sensor-mm
Degree of protection (IP)IP65
Analogue output 0 mA ... 20 mANo
Analogue output 0 V ... 10 VNo
Material of optical surfacePlastic
Analogue output -10 V ... +10 VNo
Width sensor30.5mm
AWG-number-
Analogue output 4 mA ... 20 mANo
With communication interface AS-InterfaceNo
With communication interface RS-422No
With communication interface RS-232No
With communication interface DeviceNetNo
Height of sensor92mm
With communication interface analogueNo
With communication interface SSINo
With communication interface EthernetNo
With communication interface RS-485No
With communication interface INTERBUSNo
Length of sensor77mm
With communication interface CANOpenNo
With communication interface PROFIBUSNo
With communication interface SSDNo
With other analogue outputNo
With reflectorNo
Max. switching distance60000mm
Sensing modeDark switching
Rated switching distance40000mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XUX0AKSAM12T

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • Through beam photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage type

DC

Material housing

Plastic

Ambient temperature

-25 .. 55°C

Type of interface for safety communication

Other

Type of switch function

Other

Max. output current

100mA

Number of protected contact energized outputs

0

Switching frequency

250Hz

Suitable for safety functions

Type of switching output

Other

Type of electric connection

Connector M12

Number of protected semiconductor outputs

0

With time function

Number of contact energized outputs with signalling function

0

Max. opening angle

0°

Rated control supply voltage Us at AC 50HZ

- .. -V

Number of semiconductor outputs with signalling function

0

Explosion safety category for dust

None

Operation agent-safety class

Safety class 0

Rated control supply voltage Us at DC

12 .. 24V

Setting procedure

Other

Explosion safety category for gas

None

Rated control supply voltage Us at AC 60HZ

- .. -V

Construction type housing

Cuboid

Scope of delivery of the one-way system

Transmitter and receiver

Laser protection class

None

Type of light

Infrared light

Light dot

-mm²

Type of safety according to IEC 61496-1

1

Min. reflector distance

30000mm

Response time

2ms

Max. output current at protected output

100mA

Transmission range of the safety field

-m

Switching voltage of OSSD at state "high"

-V

With monitoring function downstream switching devices

With restart blockage

Wavelength of the sensor

-nm

Pre failure notice

Material of cable sheath

Other

Diameter sensor

-mm

Degree of protection (IP)

IP65

Analogue output 0 mA ... 20 mA

Analogue output 0 V ... 10 V

Material of optical surface

Plastic

Analogue output -10 V ... +10 V

Width sensor

30.5mm

AWG-number

-

Analogue output 4 mA ... 20 mA

With communication interface AS-Interface

With communication interface RS-422

With communication interface RS-232

With communication interface DeviceNet

Height of sensor

92mm

With communication interface analogue

With communication interface SSI

With communication interface Ethernet

With communication interface RS-485

With communication interface INTERBUS

Length of sensor

77mm

With communication interface CANOpen

With communication interface PROFIBUS

With communication interface SSD

With other analogue output

With reflector

Max. switching distance

60000mm

Sensing mode

Dark switching

Rated switching distance

40000mm

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.