Aleta.hr
Main Product Image

ZCD39

Code: 1727615

ManufacturerSchneider
Catalog numberZCD39
EAN code3389110185461

Details

  • Sensors
  • End switch
  • 1 KOM
  • SCHNEIDER

Technical specifications

Switching functionQuick-break switch
Rated operation current Ie at DC-13, 230 V0.1A
With status indicationNo
Coating housingOther
Material housingMetal
Suitable for safety functionsNo
Rated operation current Ie at AC-15, 230 V0.75A
Number of contacts as change-over contact0
Degree of protection (IP)IP66/IP67
Forced openingYes
Explosion safety category for dustNone
Construction type housingCuboid
Number of safety auxiliary contacts0
Height of sensor65mm
Diameter sensor0mm
Housing according to normDIN EN 50047
Number of contacts as normally open contact1
Number of contacts as normally closed contact2
Switching function latchingNo
Rated operation current Ie at AC-15, 24 V0A
Rated operation current Ie at AC-15, 125 V0A
Explosion safety category for gasOther
Rated operation current Ie at DC-13, 125 V0A
Type of electric connectionOther
Type of interface for safety communicationNone
Length of sensor30mm
Rated operation current Ie at DC-13, 24 V0A
Output electronicNo
Type of control elementNone
Width sensor31mm
Ambient temperature during operating-25 - 70°C
Type of interfaceNone
Alignment of the control elementOther
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ZCD39

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • End switch
  • 1 KOM
  • SCHNEIDER

Technical specifications

Switching function

Quick-break switch

Rated operation current Ie at DC-13, 230 V

0.1A

With status indication

Coating housing

Other

Material housing

Metal

Suitable for safety functions

Rated operation current Ie at AC-15, 230 V

0.75A

Number of contacts as change-over contact

0

Degree of protection (IP)

IP66/IP67

Forced opening

Explosion safety category for dust

None

Construction type housing

Cuboid

Number of safety auxiliary contacts

0

Height of sensor

65mm

Diameter sensor

0mm

Housing according to norm

DIN EN 50047

Number of contacts as normally open contact

1

Number of contacts as normally closed contact

2

Switching function latching

Rated operation current Ie at AC-15, 24 V

0A

Rated operation current Ie at AC-15, 125 V

0A

Explosion safety category for gas

Other

Rated operation current Ie at DC-13, 125 V

0A

Type of electric connection

Other

Type of interface for safety communication

None

Length of sensor

30mm

Rated operation current Ie at DC-13, 24 V

0A

Output electronic

Type of control element

None

Width sensor

31mm

Ambient temperature during operating

-25 .. 70°C

Type of interface

None

Alignment of the control element

Other

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.