Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Width sensor
40mm
Rated operation current Ie at DC-13, 24 V
0A
Number of safety auxiliary contacts
0
Number of contacts as change-over contact
2
Diameter sensor
0mm
Forced opening
No
Type of interface
None
Rated operation current Ie at AC-15, 230 V
3A
Length of sensor
60mm
Number of contacts as normally open contact
0
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at DC-13, 230 V
0.27A
Rated operation current Ie at AC-15, 125 V
0A
Number of contacts as normally closed contact
0
Switching function
Quick-break switch
Height of sensor
102mm
Rated operation current Ie at DC-13, 125 V
0A
Switching function latching
No
Construction type housing
Cuboid
Type of interface for safety communication
None
Suitable for safety functions
No
Explosion safety category for dust
None
Output electronic
No
Explosion safety category for gas
None
Coating housing
Other
Alignment of the control element
Other
Material housing
Metal
Type of electric connection
Cable entry metrical
Ambient temperature during operating
-25 - 70°C
Degree of protection (IP)
IP65
With status indication
No
Type of control element
None
From same serie
ZCKJ4046H29

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Width sensor
40mm
Rated operation current Ie at DC-13, 24 V
0A
Number of safety auxiliary contacts
0
Number of contacts as change-over contact
2
Diameter sensor
0mm
Forced opening
Type of interface
None
Rated operation current Ie at AC-15, 230 V
3A
Length of sensor
60mm
Number of contacts as normally open contact
0
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at DC-13, 230 V
0.27A
Rated operation current Ie at AC-15, 125 V
0A
Number of contacts as normally closed contact
0
Switching function
Quick-break switch
Height of sensor
102mm
Rated operation current Ie at DC-13, 125 V
0A
Switching function latching
Construction type housing
Cuboid
Type of interface for safety communication
None
Suitable for safety functions
Explosion safety category for dust
None
Output electronic
Explosion safety category for gas
None
Coating housing
Other
Alignment of the control element
Other
Material housing
Metal
Type of electric connection
Cable entry metrical
Ambient temperature during operating
-25 .. 70°C
Degree of protection (IP)
IP65
With status indication
Type of control element
None
From same serie
We use cookies to enhance your experience.